首页> 外文期刊>Cornea >Central and Peripheral Corneal Endothelial Cell Analysis With Slit-Scanning Wide-Field Contact Specular Microscopy: Agreement With Noncontact Specular Microscopy
【24h】

Central and Peripheral Corneal Endothelial Cell Analysis With Slit-Scanning Wide-Field Contact Specular Microscopy: Agreement With Noncontact Specular Microscopy

机译:中央和外周角膜内皮细胞分析用狭缝扫描宽场接触镜面显微镜:与非接触式镜面显微镜协议

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: The prospective case series aimed to examine the agreement between the use of a slit-scanning contact specular microscope and a noncontact specular microscope in corneal endothelial cell (CEC) analysis and to evaluate the differences between the central and peripheral regions in normal corneas. Methods: After confirming normal corneal endothelium with slit-lamp microscopy, CEC images of 56 eyes of 56 cataractous patients were analyzed in the central and 4 peripheral regions using a slit-scanning contact specular microscope. A noncontact specular microscope was used for the analysis in the central region. The endothelial cell density (ECD), the percentage of hexagonal shape cells (HEX), and the coefficient of variation (CV) in the central region were compared. Differences between central and peripheral CECs were also evaluated. Results: The mean ECD was 2778 cell/mm(2) and was not different from the results using the noncontact specular microscope (2736 cell/mm(2), P = 0.051). There was a significant correlation (P < 0.001, R-2 = 0.72). The analysis of HEX resulted in larger values with the slit-scanning contact microscope (53.13% vs. 48.89%, P < 0.001), whereas there was no difference in the CV (38.48 vs. 38.04, P = 0.56). On comparing the central and peripheral regions, there was no significant difference in the ECD, whereas significant differences were found in the superior region in the HEX and CV (P < 0.001) and in the nasal region in CV (P = 0.023). Conclusions: The analysis of ECD with the use of the slit-scanning contact specular microscope did not differ from the noncontact specular microscope, and the results demonstrated no difference between the central and peripheral ECD.
机译:目的:潜在案例系列旨在审查在角膜内皮细胞(CEC)分析中使用狭缝扫描触点镜片显微镜和非接触镜镜显微镜之间的协议,并评估正常角膜中的中央和周边区域之间的差异。方法:使用狭缝扫描接触镜面显微镜在中央和4个外周区域分析56个白线患者的56只眼患者的CEC图像。非接触式镜面显微镜用于中央区域的分析。比较了内皮细胞密度(ECD),六边形形状细胞(六角端)的百分比和中央区域中的变异系数(CV)。还评估了中央和外围CEC之间的差异。结果:平均ECD为2778个细胞/ mm(2),并且使用非接触镜镜显微镜(2736电池/ mm(2),P = 0.051)与结果不同。存在显着的相关性(P <0.001,R-2 = 0.72)。 Hex的分析导致狭缝扫描接触显微镜(53.13%与48.89%,P <0.001)具有较大的值,而Cv没有差异(38.48 vs.38.04,p = 0.56)。在比较中央和外周区域时,ECD没有显着差异,而在十六进制的上部区域和CV(P <0.001)中的上部区域中发现显着差异(P = 0.023)。结论:使用狭缝扫描触点镜片显微镜的ECD分析与非接触镜镜显微镜没有不同的不同,结果表明中央和外围ECD之间没有差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号