首页> 外文期刊>Computers and Electronics in Agriculture >Adapting a relatively low-cost reflectance spectrometer for on-combine sensing of grain protein concentration
【24h】

Adapting a relatively low-cost reflectance spectrometer for on-combine sensing of grain protein concentration

机译:采用相对低成本的反射光谱仪,用于组合谷物蛋白质浓度的感测

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

An on-combine, near infrared (NIR) spectrometer is now commercially available for mapping grain protein concentration (GPC) within farm fields. Costing > US$20,000, this specialized instrument may not be affordable for all producers. The objective of this study was to adapt and evaluate a moderately priced reflectance spectrometer ( < US$5500, Avantes AvaSpec ULS2048 x 16-USB2) for on-combine sensing of GPC. A "leave-one-out" cross-validation partial least square (PLS) regression model for GPC was developed for flowing grain with the spectrometer's probe-head attached to the lower end of an inclined trough. Good correlation (r(2) = 0.92) was observed between estimated and reference GPC in grain samples when NIR spectra (850-1040 nm) and GPC reference values were used for developing the PLS model. The NIR estimation achieved a standard error of < 5 g of protein kg(-1) of grain. An inexpensive external temperature control system was built that stabilized the temperature of the instrument's input/output converter board within 60 m of activation. Placed on a test stand machine with standard 12.5 cm diameter auger, the instrument predicted GPC to < 5 and < 10 g kg(-1) in two and three of four wheat cultivars thus indicating that the model produced on the trough may be applied into predicting GPC on a combine. When placed on a combine, the calibrated instrument produced a protein map that correlated well (r = 0.88) with a map derived from an expensive reflectance spectrometer (US$32,000, Polytec 1721). Thus, a relatively inexpensive NIR reflectance spectrometer may be adapted for mapping GPC across fields.
机译:近红外(NIR)光谱仪现在可以商购获得用于在农场领域内的粒蛋白浓度(GPC)。成本计量> 20,000美元,这款专业仪器可能对所有生产商负担得起。本研究的目的是适应和评估适度价格的反射光谱仪(5500美元,Avantes AvaSpec ULS2048 x 16-USB2),用于GPC的接通感测。用于GPC的“休留次”交叉验证局部最小二乘(PLS)回归模型用于流动谷物,其具有光谱仪的探针头附接到倾斜槽的下端。当NIR光谱(850-1040nm)和GPC参考值用于开发PLS模型时,在谷物样品中估计和参考GPC之间观察到良好的相关性(R(2)= 0.92)。 NIR估计达到了谷物的<5g蛋白质kg(-1)的标准误差。建造廉价的外部温度控制系统,稳定在60米的激活范围内稳定仪器的输入/输出转换器板的温度。置于标准12.5厘米直径螺旋钻的试验机上,仪器将GPC预测到2个小麦品种中的2个和三个中的<5和<10g kg(-1),因此表示可以应用于槽上产生的模型预测组合的GPC。当放置在组合时,校准仪器产生了蛋白质地图,其相关的良好(R = 0.88),地图来自昂贵的反射光谱仪(32,000美元,Polytec 1721)。因此,相对便宜的NIR反射光谱仪可以适于跨越字段映射GPC。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号