Near-infrared spectroscopy during cesarean section with common iliac artery balloon occlusion for total placenta previa: a case report

机译:剖腹产近红外光谱与髂骨共髂动脉气球闭塞术治疗PREVIA:案例报告

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose of investigation: The aim of this study was to evaluate lower limb circulation during vascular occlusion in patients undergoing cesarean section with total placenta previa. Materials and Methods: Two pregnant women with total placenta previa underwent regional oxygen saturation (rSO(2)) monitoring in the lower limb, using near-infrared spectroscopy (NIRS) during cesarean section with common iliac artery balloon occlusion(CIABO). Results: There was no decrease in rSO(2) during balloon inflation and after balloon inflation in the two patients. Conclusion: The authors found that it is possible to evaluate limb ischemia by balloon occlusion in real-time using NIRS to measure regional oxygen saturation.