Ultrasound shear wave elastography in the assessment of passive biceps brachii muscle stiffness: influences of sex and elbow position

机译:超声剪切波形弹性成像在评估被动二头肌Brachii肌肉僵硬:性别和肘部位置的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Objective To assess differences in biceps brachii muscle (BBM) stiffness as evaluated by ultrasound shear wave elastography (SWE). Methods The passive stiffness of the BBM was quantified with shear wave velocity (SWV) measurements obtained from 10 healthy volunteers (5 men and 5 women, mean age 50 years, age range 42–63 years) with the elbow at full extension and 30° flexion in this IRB-approved study. Potential differences between two depths within the muscle, two elbow positions, the two arms, and sexes were assessed by using two-tailed t-test. The reproducibility of SWV measurements was tested by using intraclass correlation coefficient (ICC). Results Significantly higher passive BBM stiffness was found at full elbow extension compared to 30° of flexion (p ≤ 0.00006 for both arms). Significantly higher passive stiffness in women was seen for the right arm (p = 0.04 for both elbow positions). Good correlation of shear wave velocity measured at the different depths. The ICC for interobserver and intraobserver variation was high. Conclusions SWE is a reliable quantitative tool for assessing BBM stiffness, with differences in stiffness based on elbow position demonstrated and based on sex suggested. Highlights ? Trend towards higher passive stiffness of the BBM in women compared to men, which was significantly higher for the right arm ? Significantly higher passive BBM stiffness at full extension of the elbow compared to 30° of flexion ? High reliability and reproducibility in SWV measurements using ultrasound ARFI imaging
机译:摘要目的是评估二鼠二头肌肌肉(BBM)刚度的差异,如超声剪切波弹性显影(SWE)评估的。方法使用从10个健康的志愿者(5名男子和5名女性,50岁,42-63岁)的剪切波速度(SWV)测量来量化BBM的被动刚度,用肘部和30°在这个IRB批准的研究中屈曲。通过使用双尾T检验,评估肌肉内两种深度,两个肘部位置,两个臂和性别之间的潜在差异。通过使用脑内相关系数(ICC)来测试SWV测量的再现性。结果在全肘部延伸时发现了较高的无源BBM刚度与30°屈曲相比(两个臂的P≤0.00006)。右臂看到女性的显着较高的被动僵硬(P = 0.04对于两个肘部位置)。在不同深度测量的剪切波速度的良好相关性。 Interobserver和intraobserver变异的ICC很高。结论SWE是一种可靠的定量工具,用于评估BBM僵硬,基于肘部位置的刚度差异,并基于性别建议。强调 ?与男性的男性博士较高被动僵硬的趋势,右臂显着高得多?与30°屈曲相比,肘部全延伸的无源BBM刚度明显较高?使用超声ARFI成像的SWV测量的高可靠性和再现性

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号