首页> 外文期刊>Clinical imaging >Depiction of the native coronary arteries during ECG-triggered High-Pitch Dual-Source Coronary Computed Tomography Angiography in children: Determinants of image quality
【24h】

Depiction of the native coronary arteries during ECG-triggered High-Pitch Dual-Source Coronary Computed Tomography Angiography in children: Determinants of image quality

机译:在儿童ECG触发的高桨距双源冠状动脉造影血管造影期间对天然冠状动脉的描述:图像质量的决定因素

获取原文
获取原文并翻译 | 示例
           

摘要

ObjectiveAssess the image quality of ECG-triggered High-Pitch Dual-Source CTA for the evaluation of native coronaries in children. Materials and methodsBetween August 2014 and September 2017, 45 children with morphologically normal cardiac chambers had cardiac prospective ECG-triggered High-Pitch Dual-Source CTA. Two pediatric radiologists blinded to clinical data, independently reviewed each case. The coronary arteries were evaluated using a four-point scale quality score according to the coronary segment. Attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured using values from the air, inter-ventricular septum and ascending aorta at the level of the sinuses of Valsalva. Results225 coronary segments were assessed showed a mean score of 2.40?±?0.73, 94.2% had diagnostic image quality. The best and worst average quality were seen in segment 5 and 2, respectively. Inter-observer agreement was moderate for all segments except for segment 1, which was excellent. Worse quality scores were significantly associated with younger patients and low body mass index as well as with higher heart rates in all segments. The mean observed heart rate and BSA in patients with diagnostic image quality were below 77?bpm and over 1.4?m2respectively. There is no significant association between attenuation, SNR and CNR with image quality. ConclusionsProspective ECG-triggered High-Pitch Dual-Source Computed Tomography Angiography achieves consistent and diagnostic image quality for coronary artery assessment at a low effective dose in pediatric patients.
机译:ObjectiveAssess ECG触发的高间距双源CTA的图像质量,用于评估儿童天然冠状冠状动脉。 2014年8月和2017年8月的材料和方法,45名患有形态正常心脏腔室的儿童具有心脏未来的ECG触发的高距离双源CTA。两位儿科放射科医生对临床数据蒙蔽,独立地审查了每种情况。根据冠状动脉段使用四点刻度质量分数评估冠状动脉。衰减,信噪比(SNR)和对比度噪声比(CNR)使用来自空气间隔,间间隔和脉动的脉搏水平的脉搏水平测量。结果225评估冠状动脉段显示平均得分为2.40?±0.73,94.2%具有诊断图像质量。分别在第5和2段中看到了最佳和最差的平均质量。除分段1外,观察员间协议是适度的,除了段1,这是出色的。更糟糕的质量评分与年轻患者和低体重指数以及较高的患者的质量分数明显相关。诊断图像质量患者的平均观察到的心率和BSA低于77磅(BPM),超过1.4磅以下。衰减,SNR和CNR之间没有显着关联,具有图像质量。结论采用ECG触发的高桨距双源计算断层造影血管造影在儿科患者的低有效剂量下冠状动脉评估一致和诊断图像质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号