In this paper, the heat transfer characteristics of falling film evaporation of pure refrigerant HCFC123 were experimentally investigated in a pilot scale plate-fin heat exchanger with perforated fins. The experiments have been carried out under the conditions that the mass flux is in the range of 23 to 49 kg/m(2)s, the corresponding inlet Reynolds number from 200 to 500, the heat flux from 3.2 to 9.5 kW/m(2), and the evaporation pressure about 0.3 MPa. The variation laws of the local heat transfer coefficient versus the main parameters, including the inlet Reynolds number, heat flux and vapor quality were discussed. By introducing the two-phase convective multiplier F as a function of Lockhart-Martinelli parameter, a correlation for the two-phase forced convective component of the local boiling heat transfer coefficient was developed, and compared with correlations in open literature. By using a superposition method, the local boiling heat transfer coefficient that includes the contributions of forced convective boiling and nucleate boiling was analyzed. The predictions of local heat transfer coefficients were found to be in good agreement with experimental data.
机译:本文在具有多孔翅片的先导尺度板翅片热交换器中实验研究了纯制冷剂HCFC123的下落膜蒸发的传热特性。实验已经在质量磁通量在23-49kg / m(2)s的范围内进行,相应的入口雷诺数为200至500,从3.2至9.5 kW / m的热通量( 2),蒸发压力约为0.3MPa。讨论了局部传热系数的变异规律与主要参数,包括入口雷诺数,热通量和蒸气质量。通过将两相对流倍增器F引入锁骨 - Martinelli参数的函数,开发了对局部沸腾传热系数的两相强制对流组分的相关性,并与开放文献中的相关性相比。通过使用叠加方法,分析了包括强制对流沸腾和核心沸腾的贡献的局部沸腾传热系数。发现对局部传热系数的预测与实验数据很好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号