A flexible reactor and measurement setup to safely obtain thermokinetic data for exothermic chemical reactions in plate-type microreactors is presented. Precise heat flux measurement is realized by means of Seebeck elements and allows for direct as well as space- and time-resolved heat flux determination across the reactor. The microreactor used in this work is manufactured from poly(vinylidene fluoride) foils and consists of 11 SZ-shaped mixing channel elements. The Seebeck elements are calibrated by the Joule effect, while its performance is demonstrated in heat transfer and neutralization reaction experiments. Furthermore, the local resolution enables an estimation of mixing time scale for rapid reactions. A comparison of obtained results indicates good accordance with literature data and is the base of further investigations using the calorimeter.
机译:介绍了一种柔性反应器和测量设置,以安全地获得板型微反应器中放热化学反应的热动力学数据。 通过塞贝克元件实现精确的热通量测量,并允许直接以及在反应器上的空间和时间分辨的热通量确定。 本作作品中使用的微反应器由聚(偏二氟乙烯)箔制成,并且由11个Sz形混合通道元件组成。 塞贝克元素被焦耳效应校准,而其性能在传热和中和反应实验中证明。 此外,局部分辨率使得能够估计混合时间量表以获得快速反应。 获得结果的比较表明良好的文献数据,并且是使用量热计的进一步调查的基础。