首页> 外文期刊>Chemical Engineering & Technology: Industrial Chemistry -Plant Equipment -Process Engineering -Biotechnology >Measuring Biogas Composition with a Compact Microelectromechanical System-Based Spectrometer
【24h】

Measuring Biogas Composition with a Compact Microelectromechanical System-Based Spectrometer

机译:测量沼气组合物与基于紧凑的微机电系统的光谱仪

获取原文
获取原文并翻译 | 示例
           

摘要

To operate a demand-driven anaerobic digester, improvements to monitoring of process parameters are necessary. Therefore, a mid-infrared spectroscopic gas sensor utilizing a microelectromechanical system-based Fabry-Perot interferometer was tested for its suitability to measure the biogas concentration online. The spectral data is analyzed using principle component regression to make predictions of methane and carbon dioxide. Testing was performed in a laboratory, at a 1000-L pilot-scale digester, and at a 1.2-MW landfill site. Scans took under eight minutes during testing and it is expected that this can be reduced further to give a shorter delay from the online measurements.
机译:为了操作需求驱动的厌氧蒸煮器,需要改进对过程参数的监测。 因此,测试利用微机电系统的法式珀罗干涉仪的中红外光谱气体传感器进行了适合在线测量沼气浓度。 使用原理成分回归分析光谱数据以使甲烷和二氧化碳的预测进行预测。 测试在实验室进行,在1000-L先导蒸煮器中,以及1.2MW垃圾填埋场。 在测试期间,扫描在八分钟内降低,预计这可以进一步减少,以便从在线测量中缩短延迟。