首页> 外文期刊>Clinical oral implants research >Prospective randomized controlled clinical study comparing two types of two‐piece dental implants supporting fixed reconstructions—Results at 5?years of loading
【24h】

Prospective randomized controlled clinical study comparing two types of two‐piece dental implants supporting fixed reconstructions—Results at 5?years of loading

机译:前瞻性随机对照临床研究比较两种类型的两件牙科植入物,支撑固定重建 - 结果为5?多年的装载

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Abstract Objectives Compare clinical outcomes of two types of dental implants with non‐matching implant–abutment junctions loaded with fixed implant‐borne reconstructions at 5?years of loading. Materials and methods In 64 patients, one of two implant systems (S1, S2) was randomly used to support fixed dental prostheses (FDP). At loading (T L ), after 1 (T 1 ), 3 (T 3 ) and 5?years (T 5 ), the implant and reconstruction survival, biological and technical complications, radiographic marginal bone levels, clinical outcomes were recorded. The implants of the groups S1 and S2 contained of two‐piece titanium implants with a non‐matching implant–abutment junction. Data were analyzed on the patient level (1 implant/patient) using the non‐parametric Wilcoxon–Mann–Whitney test. Results Ninety‐seven implants were placed and loaded with fixed reconstructions in 64 patients. At T 5 , 29 S1 and 28 S2 implants were available for the patient‐level analysis. Two implants in group S1 had to be removed in the same patient due to severe peri‐implantitis, resulting in a survival rate of 96.1% on the implant level and 96.6% on the patient level. No implant in group S2 was lost. The technical complication rate on patient‐level?amounted of 24.2% (S1) and of 6.5% (S2) ( p ??.05). Biological complications?on patient‐level were observed in 15.2% (S1) and 16.1% (S2) ( p ??.05).?From TL to T5, the medians of the mean marginal bone level changes wer a gain of 0.15 mm in group S1 and a loss of 0.14 mm in group S2 (p .05). Conclusions and clinical implications Both implant systems revealed high survival rates and minimal changes of the marginal bone levels during 5?years. Few biological complications occurred in both groups. S1 revealed a high rate of technical complications. Therefore, both implant systems can be recommended for fixed reconstructions.
机译:摘要目的比较两种类型的牙科植入物的临床结果,其中包含不匹配的植入物 - 基台与固定的植入物 - 被传承的重建于5?多年的装载。 64例患者的材料和方法,随机使用两个植入系统(S1,S2)中的一种,以支持固定的牙科假肢(FDP)。在装载(t l),1(t 1),3(t 3)和5?年(t 5),植入物和重建生存,生物学和技术并发症,记录射线照相边缘骨水平,记录临床结果。基团S1和S2的植入物包含的两件式钛植入物,其具有非匹配的植入物邻接结。使用非参数型WILCOXON-MANN-WHITNEY试验对患者水平(1种植体/患者)分析数据。结果在64名患者中放置97种植入物并加载固定重建。在T 5,29 S1和28 S2植入物中可用于患者水平分析。由于严重的Peri-Implantisitis,必须在同一患者中除去组S1中的两种植入物,导致植入水平的存活率为96.1%,患者水平为96.6%。 S2组中没有植入物丢失。患者水平的技术并发症率?相当于24.2%(S1)和6.5%(S2)(P?&Δ05)。生物并发症?在15.2%(S1)和16.1%(S2)(P≥1)中观察到患者水平(p?& 05)。?从T1到T5,平均边际骨水平的中位数变化了S1组0.15mm,S2组中的0.14mm(P& .05)。结论和临床意义均植入系统揭示了5岁的高生存率和边际骨水平的最小变化。两组发生了很少的生物并发症。 S1显示出高度的技术并发症。因此,可以推荐两个植入系统用于固定重建。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号