首页> 外文期刊>Clinical oral implants research >Peri‐implant bone loss clinical and radiographic evaluation around rough neck and microthread implants: a 5‐year study
【24h】

Peri‐implant bone loss clinical and radiographic evaluation around rough neck and microthread implants: a 5‐year study

机译:颈部颈部损失临床和射线照相评估粗糙颈部和微细植入物:5年的研究

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Objective To evaluate marginal bone loss over 5?years around microthreaded implants placed in the maxillary anterior/esthetic zone and immediate restored with non‐occlusal loading. Materials and methods Seventy‐one implants (with microthreads up to the platform‐rough surface body and neck, internal connection and platform switching) were placed in healed bone in the maxillary arches of 30 men and 23 women (mean age 37.85?±?7.09?years, range 27–60). All subjects had at least 3?mm of soft tissue to allow the establishment of adequate biologic width and to reduce bone resorption. Each patient received a provisional restoration immediately after implant placement with slight occlusal contact. Mesial and distal bone height was evaluated using digital radiography on the day following implant placement (baseline) and after 1, 2, 3, 4 and 5?years. Primary stability was measured with resonance frequency analysis. Results No implants failed, resulting in a cumulative survival rate of 100% after 3?years. Marginal bone loss from implant collar to bone crest measured at baseline (peri‐implant bone defect at the fresh extraction socket) and after 5?years was 0.90?mm?±?0.26?mm. Mesial and distal site crestal bone loss ranged from 3.42?±?1.2?mm at baseline to 3.51?±?1.5?mm after 5?years and from 3.38?±?0.9?mm at baseline to 3.49?±?0.9?mm after 5?years, respectively ( P?=? 0.086). Conclusions The results of this study showed limited implant crestal bone loss 0.90?mm?±?0.26?mm and 100% of implant survival rate at 5‐year follow‐up of immediate restored implants with rough surface neck and microthreads.
机译:摘要目的评估超过5岁的边缘骨质损失5岁以下的微生物植入物围绕上颌前/美容区,并立即通过非咬合载荷恢复。材料和方法七十一身植入物(用微量磨削,直到平台粗糙的表面体和颈部,内部连接和平台切换)置于30名男子和23名女性的上颌拱的愈合骨中(平均37.85°?±7.09 ?年,范围为27-60)。所有受试者均至少有3Ωmm软组织,以便建立充足的生物宽度并减少骨吸收。每位患者在植入物放置后立即接受临时恢复,含有轻微的咬合接触。在植入物放置(基线)之后和1,2,3,4和5?年后,使用数字射线照相评估氏骨高度。用共振频率分析测量初级稳定性。结果没有植入物失效,导致3年后累积存活率为100%。从植入套环到骨嵴到基线(新鲜提取插座上的PERI-植入骨缺损)和5岁以下的骨嵴骨骼损失为0.90Ω·mm?±0.26Ω·mm。间隙和远端场地骨折骨损失范围从3.42?±1.2?mm以3.51?±1.5?±1.5?±1.5?±1.5?±±0.9±±0.9?mm以3.49?±0.9?±0.9? 5?多年(p?= 0.086)。结论本研究的结果显示出有限的植入物骨折骨损失0.90?mm?±0.26?mm,100%的植入物存活率在5年的立即恢复植入物的5年随访,具有粗糙的表面颈部和微细磨料。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号