首页> 外文期刊>Clinical oral implants research >Loading capacity of CAD/CAM-fabricated anterior feldspathic ceramic crowns bonded to one-piece zirconia implants with different cements
【24h】

Loading capacity of CAD/CAM-fabricated anterior feldspathic ceramic crowns bonded to one-piece zirconia implants with different cements

机译:加载CAD / CAM制造的前连司型陶瓷冠的容量与不同的水泥粘合到一体式氧化锆植入物

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Objective This study evaluated the loading capacity of CAD/CAM-fabricated anterior feldspathic ceramic crowns bonded to one-piece zirconia implants with different cements. Material and methods Fifty one-piece zirconia implants were embedded in epoxy resin. The abutment aspect of one implant was optically scanned and a standardized upper canine was designed with CAD-software. Fifty feldspathic ceramic crowns were milled, polished, and mounted on the implants either without any cement, with a temporary cement or with three different composite resin cements after surface pretreatment as recommended by the manufacturers (n = 10). After storage in distilled water at 37 degrees C for 24 hr, specimens were loaded until fracture on the palatal surface of the crown at an angle of 45 degrees to the long axis of the implant and loads until fracture were detected and compared. Compressive strength of the investigated cement materials was determined. Statistical analyses were done with One-way ANOVA followed by post hoc Fisher LSD test (alpha = 0.05). Results The cements revealed significantly different compressive strength values (temporary cement: 37.1 +/- 7.0 MPa; composite resin cements: 185.8 +/- 21.3, 277.9 +/- 22.1, and 389.0 +/- 13.6 MPa, respectively). Load-at-fracture values had an overall mean value of 237.1 +/- 58.2 N with no significant difference among the composite resin cements (p 0.05). Fracture load values with the temporary cement or without cement were significantly lower (p 0.002). Conclusions CAD/CAM-fabricated anterior feldspathic ceramic crowns bonded to one-piece zirconia implants provide sufficient resistance to intraoral forces.
机译:目的该研究评估了CAD / CAM制造的前连司陶瓷冠的负载能力与不同的水泥粘合到一体式氧化锆植入物。材料和方法五十一体式氧化锆植入物嵌入环氧树脂中。光学扫描一个植入物的邻接方面,并设计了具有CAD软件的标准化上犬。铣削,抛光和安装在植入物上的五十个长度陶瓷冠,在没有任何水泥的情况下,临时水泥或在表面预处理后用三种不同的复合树脂水泥,如制造商的推荐(n = 10)。在37℃下储存在37℃的蒸馏水后,将样品加载直至冠部的腭表面的断裂,以45度的角度为45度,长轴,载荷直至检测到骨折并进行比较。测定研究的水泥材料的抗压强度。用单向ANOVA进行统计分析,然后进行HOC Fisher LSD测试(alpha = 0.05)。结果水泥显示出显着不同的压缩强度值(临时水泥:37.1 +/- 7.0MPa;复合树脂水泥:185.8 +/- 21.3,277.9 +/-22.1和389.0 +/- 13.6 MPa)。负荷裂缝值的总体平均值为237.1 +/- 58.2 n,复合树脂水泥中没有显着差异(P& 0.05)。临时水泥或不含水泥的断裂载荷值显着降低(P <0.002)。结论CAD / CAM制造的前连散陶瓷冠状粘接到一体式氧化锆植入物提供足够的对眼力的抵抗力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号