首页> 外文期刊>Canadian acoustics >Contribution Of Internal Assemblies To Wood-Frame Floor/Ceiling ASTC Performance
【24h】

Contribution Of Internal Assemblies To Wood-Frame Floor/Ceiling ASTC Performance

机译:内部组件对木材框架地板/天花板ASTC性能的贡献

获取原文
获取原文并翻译 | 示例

摘要

In wood-frame buildings, internal walls directly mounted to the joists above (i.e., penetrating any drop ceiling) provide a flanking path for considerable potential vertical sound transmission, decreasing the Apparent Sound Transmission Class (ASTC) performance of the overall as-built assembly. With the National Building Code transition to regulating field ASTC performance from design partition STC performance, flanking paths such as these have the potential to change the acoustical performance of an otherwise well-built floor/ceiling assembly even with reasonable perimeter flanking controls at demising walls. This article presents a comparison of field measurements demonstrating the acoustical effects of flanking through internal walls mounted directly to the joists of the wood-frame floor/ceiling assembly above.
机译:在木框架建筑中,直接安装到上面的托梁(即,穿透任何掉落天花板)的内壁提供了相当大的潜在垂直声音传输的侧翼路径,降低了整个嵌造组件的表观声音传输等级(ASTC)性能 。 随着国家建筑码过渡到从设计分区的STC性能调节现场ASTC性能,镜头路径,诸如这些侧翼路径,即使在凹陷墙壁上具有合理的周边侧翼控制,也有可能改变典型内置的地板/天花板组件的声学性能。 本文呈现了现场测量的比较,证明了通过直接安装在上面的木框架地板/天花板组件的托架上的内壁的侧翼的声学效果。