A liquid chromatography-tandem mass spectrometry method was validated for the simultaneous quantification of anidulafungin (ANF), caspofungin (CSF) and micafungin (MCF) in human plasma. The triple quadrupole mass spectrometer was equipped with a heated-electrospray ionization probe and a Zorbax SB-C18 column. The calibration curves were generated using a weighted (1/x) linear regression for caspofungin, a weighted (1/x) quadratic function for micafungin and a log-log transformed linear regression for anidulafungin. The coefficients of variation of the normalized matrix factor were 11.2, 6.1 and 11.6% at low quality control level (QcL) and 11.5, 12.7 and 11.3% at high quality control level (QcH), for ANF, CSF and MCF, respectively, confirming the absence of matrix effects. The resulting method is sensitive (LLOQ 0.2 A mu g mL(-1) for the echinocandins; LOD 0.05 A mu g mL(-1) for MCF and 0.01 A mu g mL(-1) for CSF and ANF), precise (within- and between-run from 2.9 to 15.0% and from 6.3 to 12.8%, respectively) and accurate (within- and between-run from 93.2 to 104% and from 95.9 to 109%, respectively) covering clinical concentration ranges acceptable for pediatric patients (0.2-10 A mu g mL(-1)). This analytical method could represent an efficient tool for monitoring the real-time efficacy and the safety of different recommended antifungal regimes in the pediatric population.
机译:验证液相色谱 - 串联质谱法,用于同时定量人体血浆中的Anidulafungin(ANF),Caspofungin(CSF)和Micafungin(MCF)。三重四极孔质谱仪配有加热电喷雾电离探针和ZORBAX SB-C18柱。使用用于Caspofungin的加权(1 / x)线性回归产生校准曲线,用于Micafungin的加权(1 / x)二次函数和对Anidulafungin的Log-Log变换的线性回归。在低质量控制水平(QCL)和11.5,12.7和11.5,12.7和11.3%的高质量控制水平(QCH),分别为ANF,CSF和MCF,归一化基质因子的变异系数为11.2,6.1和11.6%,为ANF,CSF和MCF,确认没有基质效应。得到的方法是敏感的(LLOQ 0.2A mu Gml(-1)用于Echinocandins;用于CSF和ANF的MCF和0.01A m m ml(-1)的0.05 a mu g ml(-1)),精确(在2.9至15.0%之间,分别从2.9%到15.0%之间,分别为6.3至12.8%,并且在93.2至104%之间,分别从93.2到104%之间,分别为95.9%至109%之间)覆盖儿科的临床浓度范围患者(0.2-10μmGml(-1))。该分析方法可以代表一种有效的工具,用于监测儿科人群中不同推荐的抗真菌制度的实时效能和安全性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号