Purpose: To evaluate the safety, efficacy, predictability and stability of laser in situ keratomileusis (LASIK) with a 1000-Hz scanning spot excimer laser (Concept System 1000; WaveLight GmbH, Erlangen, Germany). Methods: LASIK was performed on twenty eyes with myopia or myopic astigmatism (mean spherical equivalent refraction: -3.97 ± 1.72 dioptres (D); mean cylinder: -0.84 ± 0.77 D) using a microkeratome for flap creation and the Concept System 1000 for photoablation. Patients were examined preoperatively as well as 1, 3 and 6 months after the treatment. Manifest sphere and cylinder, uncorrected (UCDVA) and best corrected (BCDVA) distance visual acuity, corneal topography and pachymetry were analysed. Results: We observed no adverse events that might have been associated with the use of a repetition rate of 1000 Hz. All eyes maintained or had improved BCDVA at 6 months after treatment when compared to preoperative values. Six months after LASIK, UCDVA was 20/20 or better in 85% and 20/25 or better in 100% of the eyes. The spherical equivalent refraction was within ±0.50 D in 95% of the eyes at 6 months after surgery. The refraction stayed stable over time; 95% of the eyes changed <0.5 D postoperatively. Conclusion: LASIK with the prototype 1000-Hz excimer laser was safe, efficient and predictable. The postoperative refraction was stable over time. There were no specific clinical side-effects that might be associated with the use of such a high repetition rate.
机译:目的:通过1000 Hz扫描点准分子激光(概念系统1000; WaveLight GmbH,德国埃尔兰根),评估激光原位角膜磨镶术(LASIK)的安全性,有效性,可预测性和稳定性。方法:对20只患有近视或近视散光(平均球面等效屈光度:-3.97±1.72屈光度(D);平均柱面度:-0.84±0.77 D)的眼睛进行LASIK手术,使用微型角膜刀制作皮瓣,使用Concept System 1000进行光消融。术前以及治疗后1、3和6个月对患者进行了检查。分析了清单球体和圆柱体,未校正(UCDVA)和最佳校正(BCDVA)的远视力,角膜地形图和测厚仪。结果:我们没有观察到与1000 Hz重复频率相关的不良事件。与术前值相比,治疗后6个月,所有眼睛均保持BCDVA或有改善。 LASIK手术后六个月,UCDVA在85%的眼中为20/20或更高,在100%的眼中为20/25或更高。术后6个月,在95%的眼睛中,球面等效屈光度在±0.50 D以内。随着时间的流逝,折射保持稳定;术后95%的眼睛变化<0.5D。结论:带有原型1000Hz准分子激光的LASIK是安全,有效和可预测的。术后屈光度随时间稳定。使用如此高的重复率可能没有特定的临床副作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号