Impact of Analysis Interval Size on the Quality of Optical Frequency Domain Imaging Assessments of Stent Implantation for Lesions of the Superficial Femoral Artery

机译:分析间隔大小对浅表性股动脉病变的支架植入光学频域成像评估的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objectives: This study aimed to investigate the influence of analysis interval size on optical frequency domain imaging (OFDI) assessment of stent therapy for lesions of the superficial femoral artery (SFA). Background. No consensus or validating data are available with respect to the methodology of intravascular imaging analysis for the peripheral arteries. Methods. OFDI was performed for 30 SFA lesions, during endovascular therapy and at the 6-month follow-up. Initially, lumen and stent borders were traced at 1-mm axial intervals. Volumes were calculated using a PC-based software, and the volume index (VI) was defined as the volume divided by the stent length. Two additional OFDI analyses were performed using 2-mm and 5-mm intervals, thereby reducing the number of cross-sectional image frames analyzed. Results. The mean stent length was 89.76 +/- 35.2 mm. The mean difference in baseline minimum lumen area (MLA) was 0.4 mm(2) between MLA values from the 1-mm and 2-mm interval analyses, and 2.2 mm(2) between MLA values from the 1-mm and 5-mm interval analyses. In volumetric analysis, there were excellent correlations and good agreements for stent, lumen, and neointimal VI measurements obtained on the basis of different analysis intervals. Conclusions. Using large intervals in OFDI analyses of SFA lesions resulted in few differences in measurement variability of volumetric parameters. However, planar analysis for MLA assessment can be susceptible to high variability when large intervals are applied. (C) 2016 Wiley Periodicals, Inc.
机译:目的:本研究旨在探讨分析间隔大小对肤质股动脉病变的荧光域成像(OFDI)评估的影响(SFA)。背景。对于外周动脉的血管内成像分析的方法,没有共识或验证数据。方法。 OFDI在血管内治疗期间进行了30个SFA病变,并在6个月的随访中进行。最初,腔和支架边框以1毫米的轴向间隔跟踪。使用基于PC的软件计算卷,并且体积索引(VI)定义为卷除以支架长度。使用2mm和5mm间隔进行两种额外的OFDI分析,从而减少分析的横截面图像帧的数量。结果。平均支架长度为89.76 +/- 35.2毫米。基线最小腔面积(MLA)的平均差异为0.4mm(2)在1-mm和2mm的间隔分析之间的MLA值之间,并且在1-mm和5 mm的MLA值之间的2.2mm(2)之间间隔分析。在体积分析中,基于不同的分析间隔获得的支架,腔和新内膜VI测量具有出色的相关性和良好的达成协议。结论。在OFDI中使用大的间隔SFA病变的分析导致体积参数的测量变异性差异很少。然而,在施加大间隔时,MLA评估的平面分析可能易于高变异性。 (c)2016 Wiley期刊,Inc。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号