首页> 外文期刊>Acta ophthalmologica Scandinavica >Shift of temporal responsivity curve of pattern reversal visually evoked potentials to lower frequencies in patients after recovery from optic neuritis
【24h】

Shift of temporal responsivity curve of pattern reversal visually evoked potentials to lower frequencies in patients after recovery from optic neuritis

机译:视神经炎恢复后,患者视觉反转模式诱发电位的时间响应曲线向较低频率的移动

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose: To investigate the responsivity of the visual system to pattern reversal stimuli of different reversal rates in optic neuritis patients after a full recovery of visual acuity.Methods: Thirty eyes with optic neuritis and 30 eyes of age-matched normal controls were studied. Steady-state pattern reversal visually evoked potentials (P-VEPs) were recorded using reversal rates of 2, 10, 20 and 30 Hz. The relationship between the amplitudes of the P-VEPs and reversal rate was analysed. The temporal responsivity curves of the two groups were compared. Results: The means +- standard deviations (SDs) of the P-VEP amplitudes in the normal controls were 7.08 +- 2.97, 8.60 +- 2.37, 4.69 +- 1.99 and 2.11 +- 1.24 muY at reversal rates of 2, 10, 20 and 30 Hz, respectively. The comparable amplitudes from the recovered optic neuritis patients were 8.01 +- 2.45, 6.57 +- 2.54, 2.73 +- 1.76 and 0.94 +- 1.27 muV. The mean amplitude of the P-VEPs elicited at a reversal rate of 2 Hz was not significantly different from that of normal controls. However, the amplitudes of the P-VEPs at reversal rates of 10, 20 and 30 Hz were significantly smaller in the recovered optic neuritis patients than in the controls. In addition, the average maximum amplitude of the P-VEPs was obtained at 10 Hz in normal subjects and at 2 Hz in the recovered optic neuritis patients.Conclusion: These results indicate that the peak of the temporal tuning curve of the P-VEP shifts to lower frequencies in recovered optic neuritis eyes, and that the reduced amplitudes at higher frequencies seem to be characteristic of the visual system of patients with recovered optic neuritis.
机译:目的:研究视力完全恢复后视觉系统对视神经炎患者不同逆转率模式逆转刺激的反应。方法:研究30只视神经炎眼和30只与年龄相匹配的正常对照。使用2、10、20和30 Hz的反转速率记录稳态模式反转视觉诱发电位(P-VEP)。分析了P-VEP幅度与反转率之间的关系。比较了两组的时间响应曲线。结果:正常对照中P-VEP振幅的平均值±标准偏差(SDs)为7.08±2.97、8.60±2.37、4.69±1.99和2.11±1.24 muY,反转率为2、10,分别为20和30 Hz。来自恢复的视神经炎患者的可比较幅度为8.01±2.45、6.57±2.54、2.73±1.76和0.94±1.27muV。以2 Hz的反转速率引起的P-VEP的平均幅度与正常对照无明显差异。然而,在恢复的视神经炎患者中,P-VEP在10、20和30 Hz反转速率下的幅度明显小于对照组。此外,正常受试者在10 Hz时和恢复的视神经炎患者在2 Hz时获得了P-VEP的平均最大振幅。结论:这些结果表明P-VEP的时间调谐曲线的峰移动到视神经炎的眼睛恢复频率较低,而在较高频率下振幅的降低似乎是视神经炎恢复患者视觉系统的特征。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号