Variations in magnitude and directionality of respiratory target motion throughout full treatment courses of stereotactic body radiotherapy for tumors in the liver

机译:在针对肝脏肿瘤的立体定向全身放疗的整个治疗过程中,呼吸目标运动的大小和方向性变化

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose. To investigate the stability of target motion amplitude and motion directionality throughout full stereotactic body radiotherapy (SBRT) treatments of tumors in the liver. Material and methods. Ten patients with gold markers implanted in the liver received 11 courses of 3-fraction SBRT on a conventional linear accelerator. A four-dimensional computed tomography (4DCT) scan was obtained for treatment planning. The time-resolved marker motion was determined throughout full treatment field delivery using the kV and MV imagers of the accelerator. The motion amplitude and motion directionality of all individual respiratory cycles were determined using principal component analysis (PCA). The variations in motion amplitude and directionality within the treatment courses and the difference from the motion in the 4DCT scan were determined. Results. The patient mean (± 1 standard deviation) peak-to-peak 3D motion amplitude of individual respiratory cycles during a treatment course was 7.9 ± 4.1 mm and its difference from the 4DCT scan was -0.8 ± 2.5 mm (max, 6.6 mm). The mean standard deviation of 3D respiratory cycle amplitude within a treatment course was 2.0 ± 1.6 mm. The motion directionality of individual respiratory cycles on average deviated 4.6 ± 1.6° from the treatment course mean directionality. The treatment course mean motion directionality on average deviated 7.6 ± 6.5° from the directionality in the 4DCT scan. A single patient-specific oblique direction in space explained 97.7 ± 1.7% and 88.3 ± 10.1% of all positional variance (motion) throughout the treatment courses, excluding and including baseline shifts between treatment fields, respectively. Conclusion. Due to variable breathing amplitudes a single 4DCT scan was not always representative of the mean motion amplitude during treatment. However, the motion was highly directional with a fairly stable direction throughout treatment, indicating a potential for more optimal individualized motion margins aligned to the preferred direction of motion.
机译:目的。在整个立体定向放射疗法(SBRT)治疗肝脏肿瘤的整个过程中,研究目标运动幅度和运动方向性的稳定性。材料与方法。十名在肝脏中植入了金标记的患者在常规线性加速器上接受了11个疗程的3级SBRT。获得了二维计算机断层扫描(4DCT)扫描以进行治疗计划。使用加速器的kV和MV成像器,在整个治疗现场的整个输送过程中确定了时间分辨的标记运动。使用主成分分析(PCA)确定所有单个呼吸周期的运动幅度和运动方向性。确定了治疗过程中运动幅度和方向性的变化以及4DCT扫描中与运动的差异。结果。在治疗过程中,每个呼吸周期的患者平均峰峰值3D运动幅度(±1标准偏差)为7.9±4.1 mm,与4DCT扫描的差值为-0.8±2.5 mm(最大值,6.6 mm)。治疗过程中3D呼吸周期幅度的平均标准偏差为2.0±1.6 mm。各个呼吸周期的运动方向性平均偏离治疗过程平均方向性4.6±1.6°。治疗过程的平均运动方向性与4DCT扫描中的方向性平均偏离7.6±6.5°。单个患者特定的空间倾斜方向在整个治疗过程中解释了所有位置差异(运动)的97.7±1.7%和88.3±10.1%,分别排除和包括治疗区域之间的基线移动。结论。由于呼吸幅度变化,单次4DCT扫描并不总是代表治疗期间的平均运动幅度。但是,该运动是高度定向的,在整个治疗过程中方向都相当稳定,这表明有可能将更优的个性化运动边缘与首选运动方向对齐。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号