摘要

The latest Building Regulations and the 2004 Edition of the Approved Document Part A (AD-A) include revised Requirement A3, which was introduced to remove anomalies in the Limitation of its predecessor, i.e. it would apply only to buildings with five or more storeys. The roots of this change are found in the meeting held at the Institution of Civil Engineers in London in March 1996, involving leading representatives of the building industry. Speaker after speaker drew attention to the reduction in robustness of smaller buildings - mainly resulting from a lack of supervision, economic pressures and inadequate detailing. Similar views were expressed by SCOSS, the Standing Committee on Structural Safety, an organisation jointly sponsored by the Institutions of Civil and Structural Engineers. These circumstances prompted the Building Regulations Division to take steps and consider the application of robustness requirements to all buildings to various degrees, depending on their height, location, occupancy and types of construction (framed or load-bearing) etc. Detailed studies were sponsored and they led to the new Requirement A3 and the guidance, which would accord with the CIRIA Report [1] and the background documents of the part of the Eurocode EC 1 - 'Accidental actions due to impact and explosions'. The reports of the studies have been placed on the Department of Communities and LocaL Government (DCLG, formerly ODPM) website www.communities.gov.uk/ (Building Regulations Approved Documents and Associated Guidance, Structure - Part A). This paper examines the effectiveness of the changes and some questions regarding compliance with the Requirement.
机译:最新的建筑规则和2004年版批准的文件部分A(AD-A)包括修订的要求A3,该要求A3被引入,以删除其前身限制的异常,即它仅适用于拥有五层或更多层的建筑物。这一变革的根源是在1996年3月伦敦民营工机构举行的会议上发现的,涉及建筑业的主要代表。演讲者提请注意减少较小建筑的鲁棒性的扬声器 - 主要是由于缺乏监督,经济压力和细节不足。 Scoss,结构安全常务委员会表示类似的观点,该组织由民事和结构工程师机构共同赞助。这些情况促使建筑法规司采取措施,并考虑将鲁棒性要求应用于各种建筑物,这取决于其高度,位置,入住和建筑类型(框架或承重)等。详细研究得到了赞助和他们导致新的要求A3和指导,这将符合CIRIA报告[1]以及由于影响和爆炸引起的欧洲州EC 1 - '意外行动的背景文件。该研究的报告已于社区和地方政府部(DCLG,以前的ODPM)网站www.communities.gov.uk/(建筑法规批准文件和相关指导,结构部分a)。本文审查了变革的有效性以及关于遵守要求的一些问题。

著录项

  • 来源
    《Building Engineer》 |2006年第9期|共3页
  • 作者

    Satish Desai;

  • 作者单位

    OBE FIStruct E FBEng FFB;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 建筑科学;
  • 关键词

  • 入库时间 2022-08-19 23:09:48

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号