Objective: A mercury sphygmomanometer has been considered a gold standard for measuring blood pressure. However, by the Minamata Convention on Mercury, the traditional mercury sphygmomanometer is being replaced by an automated oscillometric device. This study aimed to provide scientific evidence to determine whether an automated oscillometric device can replace a mercury sphygmomanometer and if it is applicable in routine practice. Methods: MEDLINE, EMBASE, the Cochrane Library, and CINAHL were searched on 4 May 2018. Studies comparing blood pressure measurements between automated oscillometric devices and mercury sphygmomanometers were included. Study characteristics were abstracted using the evidence table, and random-effects meta-analyses were conducted. Results: Data were compiled from 24 studies comprising 47 759 subjects. The results of meta-analysis showed that automated oscillometric devices measured lower than mercury sphygmomanometers for both systolic blood pressure (mean differences -1.75 mmHg, 95% confidence intervals: -3.05 to -0.45, I-2 = 91.0%) and diastolic blood pressure (mean differences -1.20 mmHg, 95% confidence intervals: -2.16 to -0.24, I-2 = 95.0%). In sub-group analyses by manufacturer, BpTRU measured lower than the mercury sphygmomanometer and OMRON showed no difference compared to the mercury sphygmomanometer for both systolic and diastolic blood pressure, but the results differed depending on the devices. Conclusion: As a result of this review, the difference in blood pressure between the mercury sphygmomanometer and the automated oscillometric device was within 5 mmHg, but the heterogeneity between the studies was very high. The automated oscillometric devices showed differences in blood pressure results according to the manufacturer and product type.
机译:目的:汞血压计被认为是测量血压的金标准。然而,通过Minamata汞公约,传统的汞血压计被自动化的示波器装置所取代。本研究旨在提供科学证据来确定自动示波器是否可以代替汞血压计,如果适用于常规实践。方法:于2018年5月4日搜索Medline,Embase,Cochrane图书馆和Cinahl。包括包括自动化示波器装置和汞血压计之间的血压测量的研究。使用证据表摘要研究了研究特征,进行随机效应元分析。结果:数据由24项研究编制,包括47个759个受试者。 Meta分析结果表明,用于收缩压(平均差异-1.75mmHg,95%置信区间:-3.05至-0.45,I-2 = 91.0%)和舒张压血压的自动化示波器测量(平均差异-1.20mmHg,95%置信区间:-2.16至-0.24,I-2 = 95.0%)。在制造商的亚组分析中,BPTRU测量低于汞血压计,欧姆龙与汞血压仪相比没有差异,但是对于收缩性和舒张血压而言,结果取决于器件。结论:由于本综述,汞血压计和自动化示波器之间的血压差异在5mmHg范围内,但研究之间的异质性非常高。自动化示波器仪器显示血压差异,根据制造商和产品类型。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号