首页> 外文期刊>Biomedical Chromatography: An International Journal Devoted to Research in Chromatographic Methodologies and Their Applications in the Biosciences >Determination of urinary methylhippuric acids using MIL MIL ‐53‐ NH NH 2 2 ( Al Al ) metal–organic framework in microextraction by packed sorbent followed by HPLC HPLC – UV UV analysis
【24h】

Determination of urinary methylhippuric acids using MIL MIL ‐53‐ NH NH 2 2 ( Al Al ) metal–organic framework in microextraction by packed sorbent followed by HPLC HPLC – UV UV analysis

机译:用HPLC HPLC-UV紫外线分析,使用MIL MIR-53-NH NH 2 2(AL AL)金属有机骨架使用MIL MIR -53-NH NH 2 2(AL)金属有机骨架测定尿甲基尿酸。

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract For the analysis of methylhippuric acids (MHAs) in human urine samples, in this study, a new method based on the metal–organic framework (MOF) of MIL‐53‐NH 2 (Al) in microextraction by packed sorbent (MEPS) was developed. The synthesis of MIL‐53‐NH 2 (Al) was characterized by Fourier transform infrared spectra, field emission‐scanning electron microscopy and X‐ray diffraction. Response surface methodology was used to investigate the influences of several parameters including type and volume of elution, type of conditional solvent, sample volume and extraction cycle on MEPS efficiency. The results showed good recoveries (94%) and excellent extraction efficiencies (96%) at three different concentrations of 50, 500 and 1500?μg?ml ?1 (as low, mid and high concentrations, respectively) of MHA isomers. Calibration curves of MHAs were linear over the concentration range of 1–1500?μg?ml ?1 , with high correlation coefficients ( r ?≥?0.998). The reproducibility of the proposed MIL‐53‐MEPS for determination of three isomers of MHA was found to be in the range of 3.5–11.1%. After optimization of the proposed technique, it was used to analyze MHAs in urine samples of workers exposed to xylenes in a petrochemical plant in Asalouyah, Iran. The results indicated that the MOF–MEPS method was selective, sensitive, rapid and efficient for the extraction of urinary MHAs. The technique is also environmentally friendly and inexpensive, and the MOF sorbent is reusable.
机译:摘要在本研究中,在本研究中分析人类尿液中的甲基熟尿酸(MHAS),通过包装吸附剂(MEP),基于MIL-53-NH 2(AL)的金属 - 有机骨架(MOF)的新方法(MEP)已开发。通过傅里叶变换红外光谱,场发射扫描电子显微镜和X射线衍射的合成特征。响应面方法用于研究几种参数的影响,包括洗脱的类型和体积,条件溶剂类型,样品体积和MEPS效率的提取周期。结果显示出良好的回收率(& 94%)和优异的提取效率(& 96%),在三种不同浓度为50,500和1500Ωμg?1(分别为低,中高浓度)MHA异构体。 MHA的校准曲线在1-1500Ωμg≤1的浓度范围内线性,具有高相关系数(R?≥≤0.998)。发现拟议的MIL-53-MEP的再现性用于测定MHA的三个异构体的范围为3.5-11.1%。优化所提出的技术后,它用于分析伊朗石油化工植物中暴露于二甲苯的工人尿样的MHA。结果表明,MOF-MEPS方法是选择性,敏感,快速,高效的,用于提取尿MHA。该技术也是环保且廉价的,MOF吸附剂可重复使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号