...
首页> 外文期刊>RSC Advances >Rapid quantification of a chemically synthesized peptide GAP162 in rat plasma by liquid chromatography/triple quadrupole tandem mass spectrometry and application to a pharmacokinetic study
【24h】

Rapid quantification of a chemically synthesized peptide GAP162 in rat plasma by liquid chromatography/triple quadrupole tandem mass spectrometry and application to a pharmacokinetic study

机译:通过液相色谱/三重四极杆串联质谱法快速定量大鼠等离子体中的大鼠等离子体中的化学合成肽间隙162,并应用于药代动力学研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Liquid chromatography/tandem mass spectrometry (LC-MS/MS) is a promising analytical platform for the quantification of therapeutic peptide in biological fluids for pharmacokinetics (PK) studies. Herein, an absolute quantification method based on liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) technique was developed to quantify GAP162, a new synthetic peptide derived from RasGAP(301-326), which is a promising candidate as antitumor drug. A synthetic peptide P119 was used as internal standard. Solid phase extraction (SPE) of the mixed-mode of ion exchange and reversed-phase was employed for sample preparation. Chromatographic separation was performed on a reversed phase C4 column (30 mm x 2.1 mm, 5 mu m) with a mobile phase consisting of acetonitrile-water containing 0.1% formic acid with gradient elution at a flow rate of 0.8 mL min(-1) for 2.0 min. Multiple reaction-monitoring (MRM) mode was performed with ion pairs of m/z: 748.2 -> 830.2, and 526.7 -> 585.5 for GAP162 and internal standard of P119, respectively. Calibration curve was linear over a concentration range of 5-500 ng mL(-1) with a correlation coefficient > 0.99. The lower limit of detection was at 5 ng mL(-1) in rat plasma for GAP162. The results of the intra-and inter-day precision and accuracy studies were well within the acceptable limits. The validated method was successfully applied to investigate the pharmacokinetics study of GAP162 after single intravenous administration to male Sprague-Dawley rats at 5 mg kg(-1).
机译:液相色谱/串联质谱(LC-MS / MS)是用于在药代动力学(PK)研究中的生物液中的治疗肽的有望分析平台。在此,开发了一种基于液相色谱 - 电喷雾电离离子质谱(LC-ESI-MS / MS)技术的绝对定量方法以量化GAP162,这是一种来自Rasgap(301-326)的新合成肽,这是一个很有希望的候选人作为抗肿瘤药物。合成肽P119用作内标。使用离子交换和反相混合模式的固相萃取(SPE)用于样品制备。在反相C4柱(30mm×2.1mm,5μmm)上进行色谱分离,其流动相由含有0.1%甲酸的乙腈水,其流速为0.8mL min(-1) 2.0分钟。使用M / Z:748.2 - > 830.2,和526.7-> 585.5的离子对进行多重反应监测(MRM)模式分别用于GAP162和P119的内标。校准曲线在5-500ng ml(-1)的浓度范围内是线性的,具有相关系数> 0.99。检测的下限在大鼠血浆中为GAP162的5 ng ml(-1)。内部和日间精确和准确性研究的结果在可接受的限度内很好。成功地应用了验证的方法,以研究单一静脉施用术后GAP162的药代动力学研究在5mg kg(-1)中的雄性Sprague-dawley大鼠。

著录项

  • 来源
    《RSC Advances》 |2015年第64期|共9页
  • 作者单位

    Beijing Inst Microbiol &

    Epidemiol State Key Lab Pathogen &

    Biosecur Beijing 100071 Peoples R China;

    China Acad Chinese Med Sci Natl Resource Ctr Chinese Mat Med State Key Lab Breeding Base Dao Di Herbs Beijing 100700 Peoples R China;

    BioDuro Shanghai Inc DMPK Dept Shanghai 200131 Peoples R China;

    Jianghan Univ Wuhan 430056 Peoples R China;

    Beijing Inst Microbiol &

    Epidemiol State Key Lab Pathogen &

    Biosecur Beijing 100071 Peoples R China;

    BioDuro Shanghai Inc DMPK Dept Shanghai 200131 Peoples R China;

    Beijing Inst Microbiol &

    Epidemiol State Key Lab Pathogen &

    Biosecur Beijing 100071 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号