Evaluating the effect of image preprocessing on an information-theoretic CAD system in mammography.

机译:在乳腺摄影中评估图像预处理对信息理论CAD系统的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

RATIONALE AND OBJECTIVES: In our earlier studies, we reported an evidence-based computer-assisted decision (CAD) system for location-specific interrogation of mammograms. A content-based image retrieval framework with information theoretic (IT) similarity measures serves as the foundation for this system. Specifically, the normalized mutual information (NMI) was shown to be the most effective similarity measure for reduction of false-positive marks generated by other prescreening mass detection schemes. The objective of this work was to investigate the importance of image filtering as a possible preprocessing step in our IT-CAD system. MATERIALS AND METHODS: Different filters were applied, each one aiming to compensate for known limitations of the NMI similarity measure. The study was based on a region-of-interest database that included true masses and false-positive regions from digitized mammograms. RESULTS: Receiver-operating characteristics (ROC) analysis showed that IT-CAD is affected slightly by image filtering. Modest, yet statistically significant, performance gain was observed with median filtering (overall ROC area index A(z) improved from 0.78 to 0.82). However, Gabor filtering improved performance for the high-sensitivity portion of the ROC curve where a typical false-positive reduction scheme should operate (partial ROC area index (0.90)A(z) improved from 0.33 to 0.37). Fusion of IT-CAD decisions from different filtering schemes markedly improved performance (A(z) = 0.90 and (0.90)A(z) = 0.55). At 95% sensitivity, the system's specificity improved by 36.6%. CONCLUSIONS: Additional improvement in false-positive reduction can be achieved by incorporating image filtering as a preprocessing step in our IT-CAD system.
机译:理由和目标:在我们较早的研究中,我们报告了基于证据的计算机辅助决策(CAD)系统,用于对乳房X光照片进行特定位置的询问。具有信息理论(IT)相似性度量的基于内容的图像检索框架是该系统的基础。具体来说,归一化的互信息(NMI)被证明是减少其他预筛查质量检测方案产生的假阳性标记的最有效的相似性度量。这项工作的目的是研究图像过滤作为IT-CAD系统中可能的预处理步骤的重要性。材料与方法:应用了不同的滤波器,每个滤波器旨在补偿NMI相似性度量的已知限制。该研究基于感兴趣区域数据库,该数据库包括来自数字化乳房X线照片的真实质量和假阳性区域。结果:接收器操作特性(ROC)分析表明,IT-CAD受到图像过滤的轻微影响。使用中值滤波可以观察到适度但统计上显着的性能提升(整个ROC面积指数A(z)从0.78改善到0.82)。但是,Gabor滤波改善了ROC曲线的高灵敏度部分的性能,在ROC曲线中应使用典型的假阳性减少方案(部分ROC面积指数(0.90)A(z)从0.33改善至0.37)。来自不同过滤方案的IT-CAD决策融合显着改善了性能(A(z)= 0.90和(0.90)A(z)= 0.55)。灵敏度为95%时,系统的特异性提高了36.6%。结论:通过在我们的IT-CAD系统中将图像过滤作为预处理步骤,可以进一步提高假阳性减少率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号