Rationale and Objectives: To compare quantitative imaging parameter measures from diffusion- and perfusion-weighted imaging magnetic resonance imaging (MRI) sequences in subjects with brain tumors that have been processed with different software platforms. Materials and Methods: Scans from 20 subjects with primary brain tumors were selected from the Comprehensive Neuro-oncology Data Repository at Washington University School of Medicine (WUSM) and the Swedish Neuroscience Institute. MR images were coregistered, and each subject's data set was processed by three software packages: 1) vendor-specific scanner software, 2) research software developed at WUSM, and 3) a commercially available, Food and Drug Administration-approved, processing platform (Nordic Ice). Regions of interest (ROIs) were chosen within the brain tumor and normal nontumor tissue. The results obtained using these methods were compared. Results: For diffusion parameters, including mean diffusivity and fractional anisotropy, concordance was high when comparing different processing methods. For perfusion-imaging parameters, a significant variance in cerebral blood volume, cerebral blood flow, and mean transit time (MTT) values was seen when comparing the same raw data processed using different software platforms. Correlation was better with larger ROIs (radii≥5mm). Greatest variance was observed in MTT. Conclusions: Diffusion parameter values were consistent across different software processing platforms. Perfusion parameter values were more variable and were influenced by the software used. Variation in the MTT was especially large suggesting that MTT estimation may be unreliable in tumor tissues using current MRI perfusion methods.
机译:原理和目的:比较由不同软件平台处理过的脑部肿瘤受试者的扩散加权成像和灌注加权成像磁共振成像(MRI)序列的定量成像参数测量。材料和方法:从华盛顿大学医学院(WUSM)的综合神经肿瘤学数据存储库和瑞典神经科学研究所中选出的20名患有原发性脑肿瘤的受试者进行了扫描。 MR图像被共同注册,并且每个受试者的数据集由以下三个软件包处理:1)特定于供应商的扫描仪软件; 2)在WUSM开发的研究软件; 3)市售的,经美国食品药品监督管理局批准的处理平台(北欧冰)。在脑肿瘤和正常非肿瘤组织内选择感兴趣的区域(ROI)。比较了使用这些方法获得的结果。结果:对于扩散参数,包括平均扩散率和分数各向异性,比较不同的处理方法时,一致性很高。对于灌注成像参数,当比较使用不同软件平台处理的相同原始数据时,可以看到脑血容量,脑血流量和平均通过时间(MTT)值存在显着差异。 ROI较大(半径≥5mm)时,相关性更好。在MTT中观察到最大的差异。结论:扩散参数值在不同的软件处理平台之间是一致的。灌注参数值更具可变性,并受所用软件的影响。 MTT的变化特别大,表明使用当前的MRI灌注方法在肿瘤组织中MTT估计可能不可靠。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号