Sensitivity of quantitative metrics derived from DCE MRI and a pharmacokinetic model to image quality and acquisition parameters.

机译:从DCE MRI和药代动力学模型得出的定量指标对图像质量和采集参数的敏感性。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

RATIONALE AND OBJECTIVES: This study aims to investigate the sensitivity of quantitative metrics derived from dynamic contrast-enhanced (DCE) magnetic resonance imaging and a pharmacokinetic (PK) model to image quality and acquisition parameters. MATERIALS AND METHODS: A computer-synthesized DCE model that consisted of a large range of values of K(trans) (transfer constant of a paramagnetic contrast agent from blood to tissue), v(p) (fractional plasma volume), and k(ep) (back flux rate) was created to test the reliability of quantitative metrics derived from a standard PK model. Effects of the contrast-to-noise ratio (CNR), total acquisition time, and sampling interval on the stability and bias of the derived metrics were investigated. RESULTS: The instability and bias of the estimated K(trans), v(p), and k(ep) values increased with sampling interval and decreased with increasing CNR. Total acquisition times had limited influence on the estimations of K(trans) and v(p) values, but increasing the total acquisition time improved the stability of the estimation of k(ep) values. However, for small k(ep) values, the stability was still poor even with a total acquisition time of 8 minutes. Also, the stability and bias of the estimated values of K(trans), v(p), and k(ep) are interrelated. CONCLUSIONS: Our synthesized DCE model represents perfectly reproduced data except for the presence of Gaussian-distributed random noise. Our analysis suggests minimum changes that may be considered potentially significant in longitudinal therapy assessment studies. Our data are complementary to experimental data from human subjects and phantoms, and provide guidance for the design of image acquisition strategies.
机译:理由和目的:这项研究旨在调查从动态对比增强(DCE)磁共振成像和药代动力学(PK)模型得出的定量指标对图像质量和采集参数的敏感性。材料与方法:计算机合成的DCE模型,由大范围的K(trans)(顺磁性造影剂从血液到组织的转移常数),v(p)(分数血浆体积)和k( ep)(反向通量率)用于测试从标准PK模型得出的定量指标的可靠性。研究了对比噪声比(CNR),总采集时间和采样间隔对衍生指标的稳定性和偏差的影响。结果:估计的K(trans),v(p)和k(ep)值的不稳定性和偏差随采样间隔而增加,而随CNR的增加而减小。总采集时间对K(trans)和v(p)值的估计影响有限,但是增加总采集时间可以提高k(ep)值的估计稳定性。但是,对于小的k(ep)值,即使总采集时间为8分钟,稳定性仍然很差。另外,K(trans),v(p)和k(ep)的估计值的稳定性和偏差是相互关联的。结论:我们的合成DCE模型可以完美再现数据,但不存在高斯分布的随机噪声。我们的分析表明,在纵向治疗评估研究中可能被认为具有潜在重大意义的最小变化。我们的数据是对来自人类受试者和人体模型的实验数据的补充,并为图像采集策略的设计提供了指导。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号