首页> 外文期刊>Academic radiology >Feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in 320-detector row coronary CT angiography.
【24h】

Feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in 320-detector row coronary CT angiography.

机译:在320排探测器行冠状动脉CT血管造影术中,采用符合体重的碘剂量方案进行小剂量对比剂注射的可行性。

获取原文
获取原文并翻译 | 示例
           

摘要

RATIONALE AND OBJECTIVES: To investigate the feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in computed tomography coronary angiography (CTCA) using a 320-detector row scanner. MATERIALS AND METHODS: Ninety-eight patients who underwent CTCA in a single heartbeat with electrocardiogram-gating were divided into two groups, receiving 0.8 mL/kg of contrast material injected at a fixed duration of 12 seconds (A; n = 48) or 0.7 mL/kg of contrast material injected at a fixed duration of 10 seconds (B; n = 50); all patients then received 20 mL of saline. Contrast densities were assessed for the ascending aorta, left ventricle, right coronary artery (RCA), and left main coronary artery (LMA). RESULTS: The mean flow rate was 4.00 + or - 0.56 mL/second in group A and 4.06 + or - 0.57 mL/second in group B (P = .51). There were no significant differences in the mean enhancement values of the ascending aorta, LMA and proximal RCA between the two groups. Also, there was no significant difference between the mean enhancement values at the three different levels of the RCA (proximal, middle, and distal segments) (group A; P = .27, group B; P = .07). CONCLUSION: The use of 0.7 mL/kg of contrast material injected at a fixed duration of 10 seconds was feasible for CTCA using 320-detector row CT, with a sufficient and reliable contrast enhancement in the ascending aorta and coronary artery.
机译:理由和目的:利用320探测器行扫描仪,在计算机断层扫描冠状动脉造影(CTCA)中,研究采用体重适合的碘剂量方案小剂量注射造影剂的可行性。材料与方法:将98例单次心电图并通过心电门控进行CTCA的患者分为两组,分别接受以固定时间12秒(A; n = 48)或0.7注射的0.8 mL / kg造影剂。以固定的10秒持续时间注入的mL / kg造影剂(B; n = 50);然后所有患者均接受20 mL生理盐水。评价升主动脉,左心室,右冠状动脉(RCA)和左主冠状动脉(LMA)的对比密度。结果:A组的平均流速为4.00 +或-0.56 mL /秒,B组的平均流速为4.06 +或-0.57 mL /秒(P = 0.51)。两组之间升主动脉,LMA和近端RCA的平均增强值无显着差异。同样,RCA的三个不同水平(近端,中间和远端节段)的平均增强值之间也无显着差异(A组; P = 0.27,B组; P = .07)。结论:使用固定时间为10秒注射0.7mL / kg的对比剂对使用320排CT扫描的CTCA是可行的,在升主动脉和冠状动脉中具有足够而可靠的对比增强。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号