首页> 外文期刊>Abdominal imaging. >Assessment of colon motility using simultaneous manometric and functional cine-MRI analysis: preliminary results.
【24h】

Assessment of colon motility using simultaneous manometric and functional cine-MRI analysis: preliminary results.

机译:使用同时进行测压和功能性cine-MRI分析的结肠动力评估:初步结果。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: Gastrointestinal functional disorders are common symptoms. The evaluation of underlying colonic motility dysfunction is difficult due to lacking adequate examination techniques. Recently cine-magnetic resonance imaging (MRI) was introduced as imaging technique for visualizing colon motility. However, the correlation of MR-visible colonic-movements and real intraluminal movements was not demonstrated yet. Therefore, this feasibility study's purpose was to stimulate high amplitude propagated pressure waves (HAPPWs) by bisacodyl application under manometric control and to simultaneously identify them with cine-MRI. MATERIALS AND METHODS: Colonoscopically, a water-perfused 8-lumen-probe was placed in descending colon. Intraluminal pressure was recorded over time. After 90 min equilibration phase, MR exam at rest (HASTE-sequence, 1.5Tesla-Avanto((R)), Siemens-Medical-Solutions) was performed. Consecutively, 10 mg bisacodyl were instilled via colonic probe to induce HAPPWs. Cine-MRI and manometry were performed simultaneously over 24 min. HAPPWs were defined as pressure waves with amplitude >50 mmHg and propagation over min. three side-holes. MRI was analyzed for corresponding luminal changes of the referring colonic segment propagated aborally. RESULTS: Ten healthy volunteers (age:19-62 years, 4 females, 6 males) were enrolled. Manometry identified 11 HAPPWs, most 9-16 min post-stimulation. All HAPPWs were identified on MRI with corresponding luminal changes (100% sensitivity). CONCLUSIONS: In accordance with our study group's previous publications, these results show that cine-MRI allows not only for reliable HAPPWs' visualization using pharmalogical stimuli, but visualized colonic movements have 100% correlation to intraluminal pressure changes in manometry (gold-standard). This may be a first step to introduce cine-MRI for non-invasive colon motility assessment in patients with functional gastro-intestinal disorders.
机译:目的:胃肠功能紊乱是常见症状。由于缺乏适当的检查技术,很难评估潜在的结肠动力功能障碍。最近,将电影磁共振成像(MRI)引入作为可视化结肠运动的成像技术。但是,MR可见结肠运动与真正的腔内运动之间的相关性尚未得到证实。因此,该可行性研究的目的是通过在压力控制下应用比沙可啶来刺激高振幅传播的压力波(HAPPW),并通过cine-MRI同时识别它们。材料与方法:在结肠镜检查中,将水灌注的8流明探针置于降结肠中。随时间记录管腔内压力。在平衡90分钟之后,进行了静态MR检查(HASTE序列,1.5Tesla-Avanto(R),Siemens-Medical-Solutions)。连续地,通过结肠探针滴加10mg比沙可啶以诱导HAPPW。 Cine-MRI和测压法在24分钟内同时进行。 HAPPW被定义为振幅> 50 mmHg且在最小时间内传播的压力波。三个侧孔。分析了MRI,以了解通过鼻腔传播的参考结肠段的相应腔变化。结果:10名健康志愿者(年龄:19-62岁,女性4名,男性6名)被纳入研究。测压法识别了11个HAPPW,大多数在刺激后9-16分钟。所有HAPPWs均在MRI上被发现并伴有相应的管腔变化(灵敏度为100%)。结论:根据我们研究小组以前的出版物,这些结果表明,cine-MRI不仅允许使用药理刺激对HAPPW进行可靠的可视化,而且可视化的结肠运动与压力计的腔内压力变化(金标准)具有100%的相关性。这可能是将cine-MRI引入功能性胃肠疾病患者的非侵入性结肠运动评估的第一步。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号