首页> 外文期刊>Biosensors & Bioelectronics: The International Journal for the Professional Involved with Research, Technology and Applications of Biosensers and Related Devices >Development of urine glucose meter based on micro-planer amperometric biosensor and its clinical application for self-monitoring of urine glucose
【24h】

Development of urine glucose meter based on micro-planer amperometric biosensor and its clinical application for self-monitoring of urine glucose

机译:基于微平面安培生物传感器的血糖仪的研制及其在尿糖自我监测中的临床应用

获取原文
获取原文并翻译 | 示例
           

摘要

The highly sensitive urine glucose meter based on amperometric glucose sensorwas developed and commercialized. It shows remarkable performances of wide measurement range in 0–2000mgdl-1, rapid response time as 6 s and robustness against influence by interferents like ascorbic acid or acetaminophen. Correlation between the developed urine glucose meter and commercialized clinical-use urine glucose analyzer showed excellent linear relationship. The monitoring of postmeal blood glucose levels by assess of urine glucose of actual subjects was performed with the developed urine glucose meter. The experimental results suggest the urine glucose level 120 min following the meal should be the appropriate index for diabetes or impaired glucose tolerance to control blood glucose level. The new portable meter was developed, and is expected for flexible use at places other than home or office.
机译:基于电流型葡萄糖传感器的高灵敏度尿液血糖仪已开发并商业化。它在0–2000mgdl-1的宽测量范围,6 s的快速响应时间以及抗坏血酸或对乙酰氨基酚等干扰物的影响下表现出卓越的性能。研制的尿液血糖仪与临床上商用的尿液葡萄糖分析仪之间的相关性显示出极好的线性关系。通过开发的尿液血糖仪,通过评估实际受试者的尿液葡萄糖来监测餐后血糖水平。实验结果表明,进餐后120分钟的尿糖水平应该是糖尿病的适当指标或控制血糖水平的糖耐量降低。新的便携式电表已经开发,有望在家庭或办公室以外的其他地方灵活使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号