【24h】

Plasma treatment of paper for protein immobilization on paper-based chemiluminescence immunodevice

机译:纸质化学发光免疫装置上用于蛋白质固定的纸的等离子体处理

获取原文
获取原文并翻译 | 示例

摘要

A novel protein immobilization method based on plasma treatment of paper on the low-cost paper-based immunodevice was established in this work. By using a benchtop plasma cleaner, the paper microzone was treated by oxygen plasma treatment for 4 min and then the antibody can be directly immobilized on the paper surface. Aldehyde group was produced after the plasma treatment, which can be verified from the fourier transform infrared spectroscopy (FT-IR) spectra and x-ray photoelectron spectroscopy (XPS) spectra. By linked to aldehyde group, the antibody can be immobilized on the paper surface without any other pretreatment. A paper-based immunodevice was introduced here through this antibody immobilization method. With sandwich chemiluminescence (CL) immunoassay method, the paper-based immunodevice was successfully performed for carcinoembryonic antigen (CEA) detection in human serum with a linear range of 0.1-80.0 ng/mL The detection limit was 0.03 ng/mL, which was 30 times lower than the clinical CEA level. Comparing to the other protein immobilization methods on paper-based device, this strategy was faster and simpler and had potential applications in point-of-care testing, public health and environmental monitoring. (C) 2015 Elsevier B.V. All rights reserved.
机译:在这项工作中,建立了一种基于血浆纸质处理的新型蛋白质固定化方法,该方法基于低成本的纸质免疫装置。通过使用台式等离子体清洁器,将纸微区通过氧等离子体处理4分钟,然后将抗体直接固定在纸表面。等离子体处理后生成醛基,可以通过傅立叶变换红外光谱(FT-IR)光谱和X射线光电子能谱(XPS)光谱进行验证。通过与醛基连接,可以将抗体固定在纸张表面,而无需任何其他预处理。通过这种抗体固定方法,在此引入了基于纸的免疫装置。采用夹心化学发光(CL)免疫测定方法,成功地在人血清中以纸型免疫装置进行了癌胚抗原(CEA)检测,线性范围为0.1-80.0 ng / mL。检测限为0.03 ng / mL,为30比临床CEA水平低10倍。与其他基于纸质设备的蛋白质固定方法相比,该策略更快,更简单,并且在即时检验,公共卫生和环境监测中具有潜在的应用。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号