首页> 外文期刊>Biosensors & Bioelectronics: The International Journal for the Professional Involved with Research, Technology and Applications of Biosensers and Related Devices >Ultrasensitive electrochemical immunosensor based on horseradish peroxidase (HRP)-loaded silica-poly(acrylic acid) brushes for protein biomarker detection
【24h】

Ultrasensitive electrochemical immunosensor based on horseradish peroxidase (HRP)-loaded silica-poly(acrylic acid) brushes for protein biomarker detection

机译:基于辣根过氧化物酶(HRP)的二氧化硅-聚(丙烯酸)刷的超灵敏电化学免疫传感器,用于蛋白质生物标志物检测

获取原文
获取原文并翻译 | 示例

摘要

We report an ultrasensitive electrochemical immunosensor designed for the detection of protein bio-markers using horseradish peroxidase (HRP)-loaded silica-poly(acrylic acid) brushes (SiO2-SPAABs) as labels. HRP could be efficiently and stably accommodated in the three-dimensional architecture of the SiO2-SPAABs and the SiO2-SPAABs-HRP exhibited high catalytic performance towards o-phenylenediamine (OPD) oxidation in the presence of H2O2, which resulted in significant differential pulse voltammetric (DPV) response change and color change. Using human IgG (HIgG) as a model analyte, a sandwich-type immunosensor was constructed. In particular, graphene oxide (GO) and SiO2-SPAABs-HRP were used to immobilize capture antibody (Ab(1)) and bind a layer of detection antibody (Ab(2)), respectively. The current biosensor exhibited a good linear response of HIgG from 100 pg/mL to 100 mu g/mL with a detection limit of 50 pg/mL (S/N= 5). The sensitivity was 6.70-fold higher than the conventional enzyme-linked immunosorbent assays. The immunosensor results were validated through the detection of HIgG in serum samples. (C) 2015 Elsevier B.V. All rights reserved.
机译:我们报告了一种超灵敏的电化学免疫传感器,旨在使用装载辣根过氧化物酶(HRP)的二氧化硅-聚(丙烯酸)刷(SiO2-SPAABs)作为标记物检测蛋白质生物标记。 HRP可以有效,稳定地容纳在SiO2-SPAABs的三维结构中,并且SiO2-SPAABs-HRP在H2O2存在下对邻苯二胺(OPD)氧化表现出高催化性能,这导致了明显的差分脉冲伏安法(DPV)响应变化和颜色变化。使用人IgG(HIgG)作为模型分析物,构建了夹心型免疫传感器。特别是,氧化石墨烯(GO)和SiO2-SPAABs-HRP分别用于固定捕获抗体(Ab(1))和结合一层检测抗体(Ab(2))。当前的生物传感器在100 pg / mL到100μg / mL的HIgG之间表现出良好的线性响应,检测极限为50 pg / mL(S / N = 5)。灵敏度是传统酶联免疫吸附测定法的6.70倍。通过检测血清样品中的HIgG验证了免疫传感器的结果。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号