首页> 外文期刊>Biosensors & Bioelectronics: The International Journal for the Professional Involved with Research, Technology and Applications of Biosensers and Related Devices >Electrochemical impedance immunosensor for sub-picogram level detection of bovine interferon gamma based on cylinder-shaped TiO2 nanorods
【24h】

Electrochemical impedance immunosensor for sub-picogram level detection of bovine interferon gamma based on cylinder-shaped TiO2 nanorods

机译:基于圆柱状TiO2纳米棒的牛阻抗γ-亚皮克级电化学阻抗免疫传感器

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Bovine interferon gamma (BoIFN-gamma) released by T cells plays very important roles in early diagnosis of Mycobacterium tuberculosis (MTB) infections and control of bovine tuberculosis. In this work, a label-free electrochemical impedance immunosensor is for the first time developed for highly sensitive determination of BoIFN-gamma. Cylinder-shaped TiO2 nanorods are synthesized by a facile hydrothermal method, and show high surface area and good hydrophicility. The immunosensor is fabricated by the immobilization of BoIFN-gamma monoclonal antibody on the TiO2 nanorods modified glassy carbon electrode. The prepared TiO2 and immunosensor are characterized using transmission electron microscopy, scanning electron microscopy, X-ray diffraction, contact angle measurement, cyclic voltammetry, and electrochemical impedance spectra. The BoIFN-gamma concentration is measured through the relative increase of impedance values in corresponding specific binding of BoIFN-gamma antigen and BoIFN-gamma antibody. The relative increased impedance values are proportional to the logarithmic value of BoIFN-gamma concentrations in a wide range of 0.0001 to 0.1 ng/mL with a low detection limit of 0.1 pg/mL. The developed BoIFN-gamma immunosensor shows a 249-fold decrease in detection limit in comparison with current enzyme-linked immunosorbent assay. This study provides a new, simple, and highly sensitive approach for very potential application in early diagnosis of MTB infections and control of bovine tuberculosis. (C) 2014 Elsevier B.V. All rights reserved.
机译:T细胞释放的牛干扰素γ(BoIFN-γ)在结核分枝杆菌(MTB)感染的早期诊断和牛结核病的控制中起着非常重要的作用。在这项工作中,首次开发了无标记的电化学阻抗免疫传感器,用于高度灵敏地测定BoIFN-γ。圆柱状的TiO2纳米棒是通过简便的水热法合成的,具有较高的表面积和良好的亲水性。通过将BoIFN-γ单克隆抗体固定在TiO2纳米棒修饰的玻碳电极上来制造免疫传感器。使用透射电子显微镜,扫描电子显微镜,X射线衍射,接触角测量,循环伏安法和电化学阻抗谱对制备的TiO2和免疫传感器进行表征。通过在BoIFN-γ抗原和BoIFN-γ抗体的相应特异性结合中的阻抗值的相对增加来测量BoIFN-γ浓度。相对增加的阻抗值与BoIFN-γ浓度的对数值成正比,范围为0.0001至0.1 ng / mL,检测极限为0.1 pg / mL。与目前的酶联免疫吸附测定法相比,开发的BoIFN-γ免疫传感器的检出限降低了249倍。这项研究为在MTB感染的早期诊断和控制牛结核中的潜在应用提供了一种新的,简单且高度敏感的方法。 (C)2014 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号