首页> 外文期刊>Journal of Molecular Liquids >A miniaturized assay for sensitive determination of Cu-2+ ions on nanolitre arrayed 4-(2-pyridylazo)resorcinol (PAR) spots on polyethersulfone membrane platform
【24h】

A miniaturized assay for sensitive determination of Cu-2+ ions on nanolitre arrayed 4-(2-pyridylazo)resorcinol (PAR) spots on polyethersulfone membrane platform

机译:用于敏感测定Cu-2 +离子对聚醚砜膜平台上的4-(2-吡啶基)间苯二酚(Par)斑点的Cu-2 +离子的敏感测定的小型化测定

获取原文
获取原文并翻译 | 示例
           

摘要

Nanolitre arrays of 4-(2-pyridylazo)resorcinol (PAR) reagent produced on polyethersulfone (PES) membrane surface has been utilized as a platform for rapid and precise determination of Cu2+ ions in water. The topography of the membrane surface was characterized by atomic force microscopy whereas internal morphology was revealed by scanning electron microscopy. The water contact angle (theta) corresponding to similar to 82 confirmed that the prepared PES membrane is a low-wetting substrate. The computed value of limit of detection (10(-3) mu g mL(-1)) achieved by the proposed membrane-based sensor was 4-order of magnitude lower than that obtained on the pristine filter-paper (10 mu g ml(-1)). The proposed method showed high robustness towards slight changes in pH, temperature and analyte volume. The interference of commonly occurring cations and anions in water was also evaluated. The analytical utility of the developed method was successfully demonstrated for determination of Cu2+ ions in spiked domestic tap water samples. The proposed method demonstrated excellent recovery of representative Cu2+ ions in real samples that was also validated by comparing the results with ICP-OES data. A good agreement between the two results was obtained at 95% confidence level. The analytical utility of the proposed method was also extended for the estimation Cu2+ ions in sewage and industrial wastewater samples and results were compared with ICP-OES analysis. The ease of usability/readability, low reagent/analyte volume requirement and superior robustness confirms the applicability of the developed low-cost method towards point-of-use applications. (C) 2017 Elsevier B.V. All rights reserved.
机译:在聚醚砜(PES)膜表面上制备的4-(2-吡啶基)间苯二酚(Par)试剂的纳米钛仪已被用作水中Cu 2 +离子的快速和精确测定的平台。膜表面的形貌特征在于原子力显微镜,而通过扫描电子显微镜显示内部形态。对应于类似于82的水接触角(θ)证实制备的PES膜是低润湿基材。通过所提出的基于膜的传感器实现的检测极限(10(-3)Mu Gml(-1))的计算值低于原始滤纸上获得的4-阶数(10μg (-1))。该方法显示出对pH,温度和分析物体积的微小变化的高稳健性。还评估了常见的阳离子和水中阴离子的干扰。成功证明了开发方法的分析效用,用于测定尖刺家用自来水样品中的Cu2 +离子。所提出的方法通过将结果与ICP-OES数据进行比较,表明了在真实样本中的代表性Cu2 +离子的优异回收。在95%的置信水平下获得两种结果之间的良好一致性。该方法的分析效用还延长了污水和工业废水样品中的估计Cu2 +离子,并与ICP-OES分析进行了比较。可用性/可读性,低试剂/分析物体积要求和优异的鲁棒性证实了开发的低成本方法对使用点应用的适用性。 (c)2017年Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号