...
首页> 外文期刊>Journal of Molecular Liquids >Electrochemical detection of gliclazide and glibenclamide on ZnIn2S4 nanoparticles-modified carbon ionic liquid electrode
【24h】

Electrochemical detection of gliclazide and glibenclamide on ZnIn2S4 nanoparticles-modified carbon ionic liquid electrode

机译:Znin2S4纳米颗粒改性碳离子液电极上的Gliclazide和Glibenclamide的电化学检测

获取原文
获取原文并翻译 | 示例

摘要

This research introduces a new modification of carbon paste electrode (CPE) by ZnIn(2)S(4 )nanoparticles (ZIS) and an ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate, (BMIM center dot PF6)) as a sensitive sensor for voltammetric detection of gliclazide and glibenclamide compared to unmodified carbon paste electrode. The modified electrode (ZISILCPE) was characterized by different techniques such as cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CHA). The electrochemical parameters of gliclazide were studied on the modified electrode surface. It was revealed that the performance of ZISILCPE sensor toward electrochemical detection of gliclazide and glibenclamide has significantly improved, in aqueous solution. The electrocatalytic features of the modified sensor were further exploited for the detection of gliclazide by DPV as a sensitive detection method. The sensor showed two well-expressed voltammetric peaks for two targets, and successfully resolved the overlap of corresponding voltammetric responses. Based on DPV, there was a linear increase for the peak currents from gliclazide and glibenclamide respectively with their concentrations ranging from 7.5 x 10(-7)-5.0 x 10(-4) M to 1.0 x 10(-6) -8.0 x 10(-4) M. According to the ZISILCPE, gliclazide and glibenclamide demonstrated the detection limits of 12 x 1 0(-7) M and 8.0 x 10(-7) M, respectively. The offered protocol was also efficient to detect two analytes in pharmaceuticals and urine samples. (C) 2019 Published by Elsevier B.V.
机译:本研究介绍了通过Znin(2)S(4)纳米颗粒(ZIS)和离子液体(1-丁基-3-甲基咪唑鎓六氟磷酸钙,(BMIM中心点PF6))作为敏感的碳糊电极(CPE)的新改性与未修饰的碳浆料电极相比,用于伏安检测Gliclazide和Glibenclamide的传感器。改性电极(ZisiLCPE)的特征在于不同的技术,例如循环伏安法(CV),差分脉冲伏安法(DPV)和计时率(CHA)。在改性电极表面上研究了Gliclazide的电化学参数。揭示水溶液中,Zisilcpe传感器对ZisiLCPE传感器朝着Gliclazide和Glibenclamide的电化学检测的性能显着改善。改性传感器的电催化特征进一步利用DPV检测Gliclazide作为敏感检测方法。传感器显示两个靶标良好的伏安峰,并成功地解析了相应的伏安响应的重叠。基于DPV,分别从7.5×10(-7)-5.0×10(-4)m至1.0×10(-6)-8.0 x的浓度范围内的Gliclazide和Glibenclamide的峰值电流的线性增加。根据ZisiLCPE,Gliclazide和Glibenclamide分别证明了12×1 0(-7)m和8.0×10(-7)m的检测限。提供的方案也有效地检测药物和尿液样本中的两个分析物。 (c)2019年由elestvier b.v发布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号