首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Column packing elimination in matrix solid phase dispersion by using water compatible magnetic molecularly imprinted polymer for recognition of melamine from milk samples
【24h】

Column packing elimination in matrix solid phase dispersion by using water compatible magnetic molecularly imprinted polymer for recognition of melamine from milk samples

机译:基质包装消除基质固相分散通过使用水相容的磁性分子印迹聚合物来识别来自牛奶样品的三聚氰胺

获取原文
获取原文并翻译 | 示例
           

摘要

This paper reports a new variant of sample clean-up procedure based on miniaturized matrix solid phase dispersion (MSPD) combining with water compatible magnetic molecularly imprinted polymers (MMIP) for preconcentration of melamine from milk samples prior high-performance liquid chromatography with UV detection. By employing MMIP as dispersant sorbent matrix interferences could be eliminated completely and the column packing step was interestingly omitted that decreasing in glassware expenditure, labor effort and extraction time which cause improvement of the method performance. In order to investigate the functionality, morphology and magnetic properties of the prepared MMIP, it was fully characterized by FT-IR, VSM, SEM, and TEM. Multivariate optimization was applied as a versatile statistical approach for evaluating the influence of the main variables and their interactions on extraction efficiency. Under optimized conditions, the proposed method exhibited a wide linear response in the concentration range of 250.0-5000.0 mu g L-1, satisfactory recoveries for all samples (86.6% <=), and supreme repeatability (RSD less than 6.3%) were achieved as well. The low limit of detection close to 67.0 mu g L-1 implied high ability of proposed method for isolation of melamine from complicate milk sample. These befitting results demonstrated that the developed method is unique in terms of the facility, rapidly and least solvent consumption as well as accurate analysis of melamine at trace levels. (C) 2019 Published by Elsevier B.V.
机译:本文报道了一种基于小型化基质固相分散体(MSPD)与水相容的磁性相位分散体(MMIP)的新样品清理程序的新变种用于与UV检测的高性能液相色谱法与三聚氰胺的前浓度。通过使用MMIP可以完全消除分散剂吸附剂基质干扰,并且有趣地省略了玻璃器皿支出,劳动力和提取时间的柱子填充步骤,这导致改善方法性能。为了研究制备的MMIP的功能,形态和磁性,它通过FT-IR,VSM,SEM和TEM完全表征。多变量优化作为一种​​多功能统计方法,用于评估主要变量的影响及其对提取效率的影响。在优化条件下,所提出的方法在250.0-5000.0μmmgl-1的浓度范围内表现出宽的线性响应,对所有样品的令人满意的回收率(86.6%<=),并且达到最高重复性(RSD小于6.3%)也是。检测的低限制接近67.0μgl-1暗示了从复杂的乳汁中分离三聚氰胺的方法的高能力。这些得到的结果表明,开发方法在设施,快速和最低溶剂消耗方面是独特的,以及在痕量水平时对三聚氰胺进行准确分析。 (c)2019年由elestvier b.v发布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号