首页> 外文期刊>Desalination: The International Journal on the Science and Technology of Desalting and Water Purification >Design study of the coupling of an air gap membrane distillation unit to an air conditioner
【24h】

Design study of the coupling of an air gap membrane distillation unit to an air conditioner

机译:气隙膜蒸馏装置与空调的耦合的设计研究

获取原文
获取原文并翻译 | 示例
           

摘要

This work presents the design of a membrane distillation (MD) unit coupled to a refrigeration device. The operation of an MD pilot plant is first tested then simulated using EES solver. The range of hot water feed temperature provided by the condenser of the refrigeration device may vary from 25 to 65 degrees C as needed by the MD unit. The results of the experimental study enable to validate a 1D theoretical model with a maximum deviation of +/- 6%. This model is combined to a heat pump model to simulate the operation of a coupled machine.
机译:该工作介绍了耦合到制冷装置的膜蒸馏(MD)单元的设计。 首先使用EES求解器模拟MD导频设备的操作。 由制冷装置的冷凝器提供的热水进给温度的范围可以根据MD单元所需的25至65摄氏度而变化。 实验研究的结果使验证1D理论模型,最大偏差为+/- 6%。 该模型组合到热泵模型以模拟连接机的操作。