首页> 外文期刊>Water Science and Technology >Calibration and field application of a molecularly imprinted membrane-passive sampler for the sampling of indicator polychlorinated biphenyls in selected aquatic environments of South Africa
【24h】

Calibration and field application of a molecularly imprinted membrane-passive sampler for the sampling of indicator polychlorinated biphenyls in selected aquatic environments of South Africa

机译:分子印迹膜 - 无源取样器的校准和野外应用,用于南非所选水产环境中指示剂多氯联苯的取样

获取原文
获取原文并翻译 | 示例
       

摘要

A passive sampling device, based on molecularly imprinted membranes (MIM), was fabricated and optimised for sampling polychlorinated biphenyls (PCBs) in aquatic ecosystems. The newly-developed passive sampler was subjected to in-situ calibration studies to determine PCB sampling rates under various conditions of water turbulence and temperature. This was carried out by exposing the passive samplers to water spiked with PCBs in a continuous-flow exposure setup. The samplers were preloaded with known concentrations of performance reference compounds (PRCs) prior to exposure. Sampling rates of seven indicator PCBs' congeners (PCBs 28, 52, 101, 118, 138, 153 and 180) ranged between 15.3 and 95.6 L/d for the different environmental conditions investigated. To determine the field suitability, the samplers were preloaded with PRCs and deployed for 10 days at the Roodeplaat and Hartbeespoort Dams, in South Africa. Water samples were taken at the end of the deployment period to compare the spot-and-grab samples to the developed samplers. PCBs 28, 101 and 138 were detected in the samplers deployed at Hartbeespoort Dam. The samplers deployed at the Roodeplaat Dam had quantifiable amounts of PCBs 28, 52, 101, 138 and 180 (0.047-0.828 ng mL(-1) d(-1)). The sampler enhanced the detectability of PCB 52 and PCB 180, which were not detected in water samples. The field suitability trials indicated that the developed sampler could successfully be used for PCB monitoring. The sampler enhanced the detection of PCBs that would otherwise be too low to detect in samples collected through the traditional spot-and-grab sampling technique.
机译:基于分子印迹膜(MIM)的无源取样装置制备并优化用于在水生生态系统中采样多氯联苯(PCB)。新开发的被动采样器受到原位校准研究,以确定在各种水湍流条件下的PCB采样率。这是通过将被动采样器暴露在连续流动曝光设置中用PCB掺入的水来进行。在暴露之前,用已知的性能参考化合物(PRC)预加载取样器。七个指示剂PCBS的采样率(PCB 28,52,118,138,153和180)的范围为15.3至95.6L / d,用于不同的环境条件。为了确定现场适用性,采样器预装了中国,并在南非的ROOKPLAAT和HARTBEESCOORT水坝部署了10天。在部署期结束时拍摄水样,以将点和抓取样本与发达的采样器进行比较。在部署在Hartbeespoort Dam的采样器中检测到PCB 28,101和138。在ROOKPLAAT坝上部署的采样器可量化量的PCB 28,52,101,138和180(0.047-0.828 ng ml(-1)d(-1))。采样器增强了PCB 52和PCB 180的可检测性,这些检测性在水样中未检测到。现场适用性试验表明,开发的采样器可以成功用于PCB监控。采样器增强了PCB的检测,否则将太低,无法在通过传统的点抓取采样技术收集的样本中检测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号