Primary calibration by reciprocity method of high-frequency acoustic-emission piezoelectric transducers

机译:通过高频声发射压电传感器的互换方法初次校准

获取原文
获取原文并翻译 | 示例
           

摘要

Although acoustic-emission (AE) piezoelectric transducers have distinctive variations in sensitivity, depending on frequency, propagation medium, and coupling, the vast majority of AE research is conducted by utilizing uncalibrated AE transducers. As a consequence, most results obtained by different groups are not comparable among each other. In this work, primary calibration by the method of reciprocity is shown. Rayleigh and longitudinal wave calibration curves are presented for piezoelectric high-frequency broadband transducer, mounted on steel and aluminium, in the frequency range 300 kHz-4 MHz. Influences on primary calibration of AE transducers, namely, by coupling medium, contact pressure, and propagation medium, are investigated. (C) 2018 Acoustical Society of America.
机译:虽然声学 - 发射(AE)压电换能器具有敏感性的独特变化,但根据频率,传播介质和耦合,虽然频率,传播介质和耦合,但是通过利用未校准的AE换能器进行绝大多数AE研究。 因此,由不同组获得的大多数结果彼此之间不相当。 在这项工作中,显示了互惠方法方法的主要校准。 为压电高频宽带换能器提供瑞利和纵波校准曲线,安装在钢和铝上,频率范围为300kHz-4 MHz。 研究了对AE换能器的主要校准,即通过偶联介质,接触压力和繁殖介质的影响。 (c)2018年声学学会。