Dependence of inertial cavitation induced by high intensity focused ultrasound on transducer F-number and nonlinear waveform distortion

机译:高强度聚焦超声引起惯性空化对换能器F数和非线性波形失真的依赖性

获取原文
获取原文并翻译 | 示例
           

摘要

Pulsed high intensity focused ultrasound was shown to enhance chemotherapeutic drug uptake in tumor tissue through inertial cavitation, which is commonly assumed to require peak rarefactional pressures to exceed a certain threshold. However, recent studies have indicated that inertial cavitation activity also correlates with the presence of shocks at the focus. The shock front amplitude and corresponding peak negative pressure (p~-) in the focal waveform are primarily determined by the transducer F-number: less focused transducers produce shocks at lower p~-. Here, the dependence of inertial cavitation activity on the transducer F-number was investigated in agarose gel by monitoring broadband noise emissions with a coaxial passive cavitation detector (PCD) during pulsed exposures (pulse duration 1ms, pulse repetition frequency 1 Hz) with p~- varying within 1-15 MPa. Three 1.5MHz transducers with the same aperture, but different focal distances (F-numbers 0.77, 1.02, 1.52) were used. PCD signals were processed to extract cavitation probability, persistence, and mean noise level. At the same p~-, all metrics indicated enhanced cavitation activity at higher F-numbers; specifically, cavitation probability reached 100% when shocks formed at the focus. These results provide further evidence supporting the excitation of inertial cavitation at reduced p~- by waveforms with nonlinear distortion and shocks.
机译:显示脉冲高强度聚焦超声检查通过惯性空化增强肿瘤组织中的化学治疗药物吸收,这通常假设需要峰值稀疏压力超过一定阈值。然而,最近的研究表明,惯性空化活动也与焦点的冲击的存在相关。焦点波形中的冲击正面幅度和相应的峰值负压(P〜 - )主要由换能器F-Number确定:较少的聚焦换能器在较低的P〜 - - 。这里,通过在脉冲曝光(脉冲持续时间1ms,脉冲重复频率1 Hz)期间通过监测宽带噪声排放,在琼脂糖凝胶中研究了术语凝聚器对换能器F数的依赖性。 - 在1-15 MPa内变化。使用具有相同孔径的三个1.5MHz传感器,但使用不同的焦距(F-Number 0.77,1.02,1.52)。处理PCD信号以提取空化概率,持久性和平均噪声水平。在相同的p〜 - ,所有指标都指示更高的F-NUMBERS增强的空化活动;具体地,当在焦点形成时,空化概率达到100%。这些结果提供了通过具有非线性变形和冲击的波形,提供了支持在降低的p〜 - 波形下的惯性空穴激发的进一步证据。

著录项

  • 来源
  • 作者单位

    Division of Gastroenterology Department of Medicine University of Washington Seattle Washington 98125 USA;

    Department of Acoustics Faculty of Physics M.V. Lomonosov Moscow State University Moscow 119991 Russia;

    Center for Industrial and Medical Ultrasound Applied Physics Laboratory University of Washington 1013 NE 40th Street Seattle Washington 98105 USA;

    Department of Urology School of Medicine University of Washington Seattle Washington 98195 USA;

    Center for Industrial and Medical Ultrasound Applied Physics Laboratory University of Washington 1013 NE 40th Street Seattle Washington 98105 USA;

    Division of Radiotherapy and Imaging The Institute of Cancer Research London SM2 5PT United Kingdom;

    Division of Radiotherapy and Imaging The Institute of Cancer Research London SM2 5PT United Kingdom;

    Department of Acoustics Faculty of Physics M.V. Lomonosov Moscow State University Leninskie Gory Moscow 119991 Russia;

    Department of Acoustics Faculty of Physics M.V. Lomonosov Moscow State University Leninskie Gory Moscow 119991 Russia;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 声学;
  • 关键词

    Dependence; inertial cavitation; induced by;

    机译:依赖;惯性空化;引起的;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号