...
首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >Magneto-controlled flow-injection device for electrochemical immunoassay of alpha-fetoprotein on magnetic beads using redox-active ferrocene derivative polymer nanospheres
【24h】

Magneto-controlled flow-injection device for electrochemical immunoassay of alpha-fetoprotein on magnetic beads using redox-active ferrocene derivative polymer nanospheres

机译:使用氧化还原活性二茂铁衍生物聚合物纳米球磁珠对α-胎蛋白的电化学免疫测定的磁控式流动喷射装置

获取原文
获取原文并翻译 | 示例
           

摘要

A new electrochemical immunosensing protocol by coupling with a magneto-controlled flow-through microfluidic device was developed for the sensitive detection of alpha-fetoprotein (AFP) on magnetic beads (MB) using ferrocene derivative polymer nanospheres (FDNP) as the electroactive mediators. The immunosensing probe was prepared by covalent conjugation of monoclonal mouse anti-human AFP antibodies with magnetic beads, while the recognition element was constructed by means of immobilizing polyclonal rabbit anti-human AFP antibodies on the redox FDNP. Upon target AFP introduction, the sandwich-type immunoreaction was carried out between the immunosensing probe and the recognition element, and the formed immunocomplex was captured in the detection cell with an external magnet. Ferrocene polymer nanospheres synthesized by infinite coordination polymerization were utilized as the signal-generation tags during the electrochemical measurement. Under optimal conditions, the magneto-controlled flow-through immunosensing platform exhibited good electrochemical responses toward target AFP within a dynamic working range of 0.01-100 ng mL(-1) and with a low detection limit of 5.7 pg mL(-1). The nanoparticles-based sensing systems also gave good reproducibility, high specificity and long-term stability. Moreover, our strategy displayed well-matched accuracy for the analysis of human serum specimens relative to commercial Roche 2010 Electrochemiluminescence (ECL) Automated Analyzer.
机译:通过与磁控式流通微流体装置耦合的新电化学免疫化方案用于使用二茂铁衍生物聚合物纳米球(FDNP)作为电活性介质的磁珠(MB)对磁珠(MB)的敏感检测。通过用磁珠的单克隆小鼠抗人AFP抗体共价缀合制备免疫抑制探针,而识别元件是通过固定在氧化还原FDNP上的多克隆兔抗人AFP抗体构成的。在靶AFP介绍后,在免疫抑制探针和识别元件之间进行夹层型免疫反应,并用外部磁铁在检测单元中捕获形成的免疫杂波。通过无限配位聚合合成的二茂铁聚合物纳米球作为电化学测量期间的信号发生标签。在最佳条件下,磁控流通免疫抑制平台在0.01-100ng mL(-1)的动态工作范围内朝向靶AFP呈现出良好的电化学响应,并且检测限为5.7pg ml(-1)。基于纳米粒子的传感系统也具有良好的再现性,高特异性和长期稳定性。此外,我们的策略显示了相对于商业Roche 2010电化学发光(ECL)自动分析仪分析人血清标本的良好准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号