首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >Portable paper sensors for the detection of heavy metals based on light transmission-improved quantification of colorimetric assays
【24h】

Portable paper sensors for the detection of heavy metals based on light transmission-improved quantification of colorimetric assays

机译:基于光传输的重金属检测的便携式纸张传感器改善了色度测定的量化

获取原文
获取原文并翻译 | 示例
           

摘要

An accurate quantification method with a wide linearity range is paramount for the development of low-cost, portable and point-of-care sensors. This work reports a new approach to analyze the colorimetric assays on paper-based sensors using the quantification from a light transmission method. Compared to the commonly-developed color intensity measurement on scanned digital images, a portable transmission densitometer is capable of directly quantifying the optical density of colorimetric results. The detection of heavy metals in an aqueous system, including Fe(II), Cu(II), and Ni(II), was carried out to demonstrate the good performance and reliability of this method. Our measurements show that the linear quantification range spans from 0.5-500 mg L-1 for the assays of Cu(II) and Fe(II) and from 2-500 mg L-1 for Ni( II) based on the reading of transmitted light through the assay spot. As a comparison, the linear range is restricted to 0.5-50 mg L-1 for the same assays when analysed by the common reflection method, suggesting a significant improvement in the accuracy and sensitivity of high analyte concentrations from the light transmission method. By expanding the linearity range, this method further streamlines the sampling procedure during analysis and will greatly advance the future development of paper-based analytical sensors.
机译:具有宽线性范围的准确定量方法对于开发低成本,便携式和护理点传感器至关重要。这项工作报告了一种新的方法来分析基于纸张的传感器上的比色测定,使用透光法量化。与扫描数字图像上的共同发育的颜色强度测量相比,便携式传输密度计能够直接定量比色度的光学密度。进行了在水性系统中的重金属的重质金属,包括Fe(II),Cu(II)和Ni(II),以证明该方法的良好性能和可靠性。我们的测量表明,基于传输的读数,线性定量范围为Cu(II)和Fe(II)和2-500mg L-1的测定为0.5-500mg L-1。通过测定点。作为比较,当通过常见反射方法分析时,线性范围限制在同一测定中的0.5-50mg L-1,表明来自光传输方法的高分子浓度的精度和灵敏度的显着改善。通过扩展线性度范围,该方法进一步简化了分析过程中的采样过程,并将大大提高了基于纸质分析传感器的未来发展。

著录项

  • 来源
  • 作者单位

    South China Univ Technol Sch Light Ind Sci &

    Engn State Key Lab Pulp &

    Paper Engn Guangzhou 510641 Peoples R China;

    South China Univ Technol Sch Chem &

    Chem Engn Guangzhou 510641 Peoples R China;

    South China Univ Technol Sch Light Ind Sci &

    Engn State Key Lab Pulp &

    Paper Engn Guangzhou 510641 Peoples R China;

    South China Univ Technol Sch Light Ind Sci &

    Engn State Key Lab Pulp &

    Paper Engn Guangzhou 510641 Peoples R China;

    South China Univ Technol Sch Light Ind Sci &

    Engn State Key Lab Pulp &

    Paper Engn Guangzhou 510641 Peoples R China;

    South China Univ Technol Sch Light Ind Sci &

    Engn State Key Lab Pulp &

    Paper Engn Guangzhou 510641 Peoples R China;

    South China Univ Technol Sch Light Ind Sci &

    Engn State Key Lab Pulp &

    Paper Engn Guangzhou 510641 Peoples R China;

    South China Univ Technol Sch Light Ind Sci &

    Engn State Key Lab Pulp &

    Paper Engn Guangzhou 510641 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号