AbstractAn office paper-based colorimetric device is proposed as a portable, rapid, and low-cost sensor for forensic applications aiming to detect phenacetin used as adulterant in illicit seized materials such as cocaine. The proposed method uses white office paper as the substrate and wax printing technology to fabricate the detection zones. Based on the optimum conditions, a linear analytical curve was obtained for phenacetin concentrations ranging from 0 to 64.52μgmL?1, and the straight line was in accordance with the following equation: (Magenta percentage color) = 1.19 + 0.458 (CPhe/μgmL?1), R2= 0.990. The limit of detection was calculated as 3.5μgmL?1(3σ/slope). The accuracy of the proposed method was evaluated using real seized cocaine samples and the spike-recovery procedure.Graphical abstractDisplay OmittedHighlights?
机译:<![cdata [ 抽象 基于办公室纸制的比色器件被提出为便携式,快速和低成本的传感器,用于旨在检测用作掺杂剂的苯甲蛋白的法医应用在非法缉获的材料,如可卡因。该方法使用白色办公纸作为基板和蜡印刷技术来制造检测区域。基于最佳条件,获得从0至64.52μgml的苯甲素浓度的线性分析曲线Δ1,直线符合以下内容等式:(品红色百分比颜色)= 1.19 + 0.458(C PHE /μgml?1 ),R 2 = 0.990。检测的极限计算为3.5μgml 1 (3σ/斜率)。使用真正查找的可卡因样品和尖峰恢复程序评估所提出的方法的准确性。 图形摘要 显示 亮点 < CE:列表项ID =“U0005”>