Abstract Development of flow systems incorporating membraneless vaporization units and flow-through contactless conductivity detector for determination of dissolved ammonium and sulfide in canal water
首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Development of flow systems incorporating membraneless vaporization units and flow-through contactless conductivity detector for determination of dissolved ammonium and sulfide in canal water
【24h】

Development of flow systems incorporating membraneless vaporization units and flow-through contactless conductivity detector for determination of dissolved ammonium and sulfide in canal water

机译:开发掺入膜汽化单元的流动系统和流通非接触式导电检测器,用于测定管水中溶解铵和硫化物

获取原文
获取原文并翻译 | 示例
           

摘要

AbstractUse of membraneless vaporization (MBL-VP) unit with two cone-shaped reservoirs is presented for on-line separation and detection of non-volatile species. A flow system comprising two sets of MBL-VP units with a single in-house capacitively coupled contactless conductivity detector (C4D) was developed for dual determination of ammonium and sulfide ions. Using the continuous-flow section, two zones (280μL) of a sample, either mixed with sodium hydroxide (for ammonium) or hydrochloric acid (for sulfide), are separately delivered into the donor reservoir of the MBL-VP units. The acceptor reservoir contains either 150μL of 15μM HCl solution (for ammonia) or pure water (for hydrogen sulfide), respectively. Vaporization and trapping of the ammonia or hydrogen sulfide gas from the donor reservoir into the liquid acceptor cone occur concurrently in the two separate MBL-VP units. After trapping the gas for 3min, the two 150-μL liquid acceptors are sequentially aspirated through the C4D flow cell for recording the changes in the conductivity. Linear calibrations were obtained for ammonium from 5 to 80μM (Volt = (0.0134 ± 0.0003) [NH4+] – (0.01 ± 0.01), r2= 0.998) and for sulfide from 5 to 200μM (Volt = (0.0335 ± 0.0009) [S2-] – (0.13 ± 0.09), r2= 0.996). Analysis time for both analytes is only 320s. Our method was applied to analyze canal water samples. The results agree well with membrane gas-diffusion flow injection techniques, using bromothymol blue for ammonium and methylene blue for sulfide. Recoveries ranged from 95% to 104%.
机译:<![cdata [ 抽象 在线分离和检测非易失性物种的膜状蒸发(MBL-VP)单元使用膜蒸发(MBL-VP)单元的使用。开发了一种流动系统,其包括两组具有单个内部内部内部容量耦合的非接触式非接触式导电探测器(C4D)的MBL-VP单元以进行双重测定铵和硫化物离子。使用连续流动部分,与氢氧化钠(用于铵)或盐酸(用于硫化物)的样品的两区(280μl)分别递送到MBL-VP单元的供体储存器中。受体贮存器分别含有150μl15μmHCl溶液(用于氨)或纯水(用于硫化氢)。在两个单独的MBL-VP单元中同时发生来自供体储存到液体受体锥中的氨或硫化氢气体的蒸发和捕获。在捕获气体3min之后,通过C4D流动单元顺序地吸出两个150-μl液体受体,以记录导电性的变化。获得5至80μm(Volt =(0.0134±0.0003)的铵的线性校准[NH 4 + ] - (0.01±0.01),R 2 = 0.998),硫化物从5到200μm(伏=(0.0335±0.0009)[s 2 - ] - (0.13±0.09),R 2 = 0.996)。两种分析物的分析时间仅为320s。我们的方法用于分析管水样。结果与膜气扩散流动注射技术完全吻合,使用溴酚蓝色硫化物和亚甲基蓝色。回收率范围从95%到104%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号