...
首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >An integrated automatic system to evaluate U and Th dynamic lixiviation from solid matrices, and to extract/pre-concentrate leached analytes previous ICP-MS detection
【24h】

An integrated automatic system to evaluate U and Th dynamic lixiviation from solid matrices, and to extract/pre-concentrate leached analytes previous ICP-MS detection

机译:一种综合的自动系统,用于评估U固体矩阵的u和Th动态液化,提取/预浓缩浸出分析物之前的ICP-MS检测

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Leached fractions of U and Th from different environmental solid matrices were evaluated by an automatic system enabling the on-line lixiviation and extraction/pre-concentration of these two elements previous ICP-MS detection. UTEVA resin was used as selective extraction material. Ten leached fraction, using artificial rainwater (pH 5.4) as leaching agent, and a residual fraction were analyzed for each sample, allowing the study of behavior of U and Th in dynamic lixiviation conditions. Multivariate techniques have been employed for the efficient optimization of the independent variables that affect the lixiviation process. The system reached LODs of 0.1 and 0.7ngkg?1 of U and Th, respectively. The method was satisfactorily validated for three solid matrices, by the analysis of a soil reference material (IAEA-375), a certified sediment reference material (BCR- 320R) and a phosphogypsum reference material (MatControl CSN-CIEMAT 2008). Besides, environmental samples were analyzed, showing a similar behavior, i.e. the content of radionuclides decreases with the successive extractions. In all cases, the accumulative leached fraction of U and Th for different solid matrices studied (soil, sediment and phosphogypsum) were extremely low, up to 0.05% and 0.005% of U and Th, respectively. However, a great variability was observed in terms of mass concentration released, e.g. between 44 and 13,967ngUkg?1. Graphical abstract Display Omitted Highlights ? Integrated system for U and Th dynamic lixiviation, extraction and pre-concentration. ? Evaluation of U and Th dynamic lixiviation from soil, sediment and phosphogypsum. ? Accumulative percentage of leached fractions were up to 0.06 and 0.006% for U and Th. ? U releases vary between 44 and 13,967ngkg-1 from different solid matrices. ]]>
机译:<![CDATA [ 抽象 从不同的环境固体基质U和Th沥滤流分通过一个自动系统,使上线浸滤和萃取评估/的预浓缩这两个元件之前的ICP-MS检测。 UTEVA树脂用作选择性提取材料。十浸出级分,用人工雨水(pH为5.4)作为浸出剂和残余馏分进行分析的每个样品,从而允许动态浸提条件U和Th行为的研究。多变量技术已经被用于影响浸出过程中的自变量的有效的优化。该体系达到的0.1和0.7的LOD 纳克公斤 1 的分别铀和钍。该方法满意地验证了三个固体基质,由土壤参考材料的分析(IAEA-375),经过认证的沉积物参考材料(BCR-320 R)和磷石膏参考材料(MatControl CSN-CIEMAT 2008)。此外,环境样品进行了分析,显示出类似的行为,即放射性核素的内容与所述连续萃取减小。在所有情况下,U和Th的用于研究不同的固体基质(土壤,沉积物和磷石膏)累计分数沥滤极低,至多0.05%和铀和钍,0.005%。然而,在质量浓度方面观察到很大的可变性释放,例如44和13967之间纳克û公斤 λ1 图形抽象 显示中省略 亮点 集成系统,用于U和钍动态浸出,萃取和预浓缩 <?CE:对ID = “P0010” 视图= “所有”> U形评价和从土壤,沉积物和磷石膏的Th动态浸滤 <?CE:对ID = “P0015” 视图= “所有”>浸出级分的累积百分比分别达到0.06和铀和钍0.006%。 <?CE:对ID = “P0020” 视图= “所有”>Ù会有所不同44和13967之间纳克公斤 - 1 从不同的固体基质 ]]>

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号