首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >A novel calibration strategy based on background correction for quantitative circular dichroism spectroscopy
【24h】

A novel calibration strategy based on background correction for quantitative circular dichroism spectroscopy

机译:一种基于背景圆形二色性光谱的基于背景校正的新型校准策略

获取原文
获取原文并翻译 | 示例
       

摘要

When using circular dichroism (CD) spectroscopy for quantitative analysis, the samples to be analyzed must be free of light-absorbing interferences. However, in real-world samples, the presence of background absorbers is practically unavoidable. The difference in the matrices between the real-world samples to be analyzed and the standard samples (on which either univariate or multivariate calibration model was built) would result in systematic errors in the quantification results of CD spectroscopy. In this contribution, a novel calibration strategy for quantitative CD spectroscopic analysis was proposed. The main idea of the proposed calibration strategy is to project the CD spectra of both the standard samples and the real-world sample to be analyzed onto a projection space orthogonal to the space spanned by the background CD spectrum of the real-world sample and then build a multivariate calibration model on the transformed CD spectra of the standard samples. The performance of the proposed calibration strategy was tested and compared with conventional univariate and multivariate calibration methods in the quantification of Pb2+ in cosmetic samples using CD spectroscopy in combination with a G-quadruplex DNAzyme (e.g. PS2.M). Experiments results revealed that the proposed calibration strategy could mitigate the influence of the difference in the matrices between the standard samples and cosmetic samples and realized quantitative analysis of Pb2+ in cosmetic samples, with precision and accuracy comparable to atomic absorption spectroscopy. The proposed calibration strategy has the features of simplicity and effectiveness, its combination with CD spectroscopic probes can realize accurate and precise quantification of analytes in complex samples using CD spectroscopy.
机译:当使用圆形二色性(CD)光谱进行定量分析时,待分析的样品必须没有吸收干扰。然而,在现实世界上的样本中,背景吸收剂的存在实际上是不可避免的。要分析的实际样本与矩阵之间的差异和标准样本(在其上构建了单变量或多变量或多变量或多变量或多变量或多变量或多变量校准模型)将导致CD光谱的量化结果中的系统误差。在这一贡献中,提出了一种用于定量CD光谱分析的新型校准策略。所提出的校准策略的主要思想是将标准样本和实际样本的CD光谱投影到要与现实世界样本的背景CD谱跨越的空间正交的投影空间分析到投影空间上在标准样品的转换CD光谱上构建多变量校准模型。测试了所提出的校准策略的性能,并与常规单变量和多元校准方法进行比较,以使用CD光谱与G-QuadrepledDNazyme(例如PS2.M)组合的CD光谱法在化妆品样品中的Pb2 +中进行比较。实验结果表明,所提出的校准策略可以减轻标准样品和化妆品样品之间矩阵之间差异的影响,并实现了化妆品样品中Pb2 +的定量分析,具有与原子吸收光谱相当的精度和精度。所提出的校准策略具有简单性和有效性的特征,其与CD光谱探针的组合可以使用CD光谱法实现复杂样品中分析物的准确和精确定量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号