首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Optimization of the post-acquisition data processing for the non-targeted screening of trace leachable residues from reusable plastic bottles by high performance liquid chromatography coupled to hybrid quadrupole time of flight mass spectrometry
【24h】

Optimization of the post-acquisition data processing for the non-targeted screening of trace leachable residues from reusable plastic bottles by high performance liquid chromatography coupled to hybrid quadrupole time of flight mass spectrometry

机译:通过高性能液相色谱法通过高效液相色谱法从可重复使用的塑料瓶中进行非靶向筛选的非靶向筛选的后测地数据处理的优化。耦合到飞行量谱的混合四极其时刻

获取原文
获取原文并翻译 | 示例
       

摘要

Food safety regulations for food contact materials (FCM) usually rely on the assessment of chemical migration in order to reduce human exposure to chemical residues that could leach from the FCM into the food. In this field, there is a need for non-targeted analytical tools which can identify unknown or unexpected leachable residues, and therefore avoid unwanted human exposure. In this study, a method based on high performance liquid chromatography coupled to hybrid quadrupole time of flight mass spectrometry (HPLC-QTOF-MS) was developed and optimized to investigate leachable residues from 30 reusable plastic bottles. Firstly, a method was validated for the targeted analysis of the 11 bisphenol analogues. None of the bisphenols were detected in the food simulants (ethanol/water; 50:50 v/v), indicating that all tested bottles are free of BPA, and that bisphenol analogues were not applied as BPA replacement in bottle manufacture. The effect of post-acquisition data processing parameters on the feature extraction in non-targeted analysis was then systematically investigated. Several parameters significantly reduced the number of correct identifications of some target trace residues, which confirms that data post-processing has to be carefully optimized to decrease the risk of false negatives. The optimized method was effectively applied to the 30 bottle samples, and monomethyl terephthalate was identified at trace level in food simulants in contact with Tritan (TM) bottles (migration rate of 0.054 +/- 0.002-0.53 +/- 0.021 mu g cm(-2) per 10 days at 40 degrees C). This method can therefore be applied to study the leachable residues from other FCMs and offer some novel information for human risk assessments.
机译:食品接触材料(FCM)的食品安全法规通常依赖于化学迁移的评估,以减少人员暴露于可以从FCM浸出到食物中的化学残留物中。在该领域中,需要无针对性的分析工具,可以识别未知或意外可浸渍残留物,因此避免了不必要的人的暴露。在该研究中,开发了一种基于高效液相色谱的方法,耦合到飞行质谱法(HPLC-QTOF-MS)的杂交四极其时间(HPLC-QTOF-MS),并优化,以研究可脱离的残留物,可从30个可重复使用的塑料瓶中进行可浸出的残留物。首先,验证了对11个双酚类似物的靶向分析的方法。在食品模拟中没有任何双酚(乙醇/水; 50:50 v / v)检测到,表明所有测试的瓶子都没有BPA,并且在瓶制造中没有作为BPA替代品的双酚类似物。然后系统地研究了采集后数据处理参数对非有针对性分析中的特征提取的影响。几个参数显着降低了一些目标迹象的正确标识的数量,这证实必须仔细优化数据处理以减少假底片的风险。优化的方法有效地应用于30瓶样品,并在与三阵(TM)瓶接触的食品模拟中鉴定单甲酯对苯二甲酸甲酯(迁移率为0.054 +/- 0.002-0.53 +/-0.021μg厘米( -2)每10天C)。因此,可以应用这种方法来研究来自其他FCMS的可脱离残留物,并为人类风险评估提供一些新颖的信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号