首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Simple and fast fabrication of microfluidic paper-based analytical device by contact stamping for multiple-point standard addition assay: Application to direct analysis of urinary creatinine
【24h】

Simple and fast fabrication of microfluidic paper-based analytical device by contact stamping for multiple-point standard addition assay: Application to direct analysis of urinary creatinine

机译:通过接触冲压对微流体纸的分析装置简单,快速制备用于多点标准加法测定:用于直接分析尿肌酐的应用

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In this work, a microfluidic paper-based analytical device (mu PAD) for simultaneous multiple-point standard addition assay was fabricated by rubber stamping the hydrophobic barrier pattern onto a laboratory filter paper. The mu PAD has a central zone from which an applied sample flows into eight surrounding narrow channels to which had been added the standard solutions. Each channel is connected to a circular area loaded with the reagent. The opposite end of this reagent zone is connected by second narrow channel to the final circular detection zone. The mu PAD was applied to the measurement of creatinine in human urine. After addition of a urine sample, the orange-colored product arising from the Jaffe reaction is formed at the eight detection zones. A digital image of the mu PAD is then recorded and the ratio of the red/green (R/G) intensity obtained using the ImageyyyyyyyJ (TM) program is used in the quantitation of creatinine. The normal standard addition calibration line is constructed using the intensity ratio against the added creatinine concentrations (50-1000 mg L-1). Good linearity was achieved (r(2) 0.99). There were no significant differences between the creatinine content using an HPLC method (paired t-test at 95% confidence, t(stat) = 1.78, t(critical) = 2.26, n = 10). The use of simultaneous multiple-point standard addition calibration allows rapid determination of creatinine in urine with elimination of matrix interference.
机译:在这项工作中,通过将疏水屏障图案冲压到实验室滤纸上,制造用于同时多点标准加成测定的微流体纸的分析装置(MU PAD)。 MU垫具有中央区域,施加的样品流入八个周围的窄通道,向其添加了标准解决方案。每个通道连接到装有试剂的圆形区域。该试剂区的相对端通过第二窄通道连接到最终圆形检测区。 MU垫应用于人尿液中肌酐的测量。加入尿液样品后,在八种检测区形成由贾维亚反应产生的橙色产品。然后记录MU垫的数字图像,并且使用使用ImageyyyyyyyyyJ(TM)程序获得的红色/绿色(R / G)强度的比率用于肌酐的定量。使用针对添加的肌酐浓度(50-1000mg L-1)的强度比构造正常的标准添加校准线。实现了良好的线性(R(2)0.99)。使用HPLC方法(以95%置信度成对T检验,T(统计)= 1.78,T(临界)= 2.26,n = 10)之间没有显着差异。同时多点标准添加校准的使用允许快速测定尿液中的肌酐,消除基质干扰。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号