On-beam computed tomography reconstruction for radiotherapy verification from projection image differences caused by motion during treatment

机译:在治疗过程中运动引起的投影图像差异的放射疗法验证的束束计算断层切断重建

获取原文
获取原文并翻译 | 示例
       

摘要

The purpose of this study is to propose a reconstruction method of a target and its neighborhood, representative of the moment of radiotherapy delivery, based on differences in its transit images between the time of planning computed tomography (pCT) and the time of treatment beam delivery. To validate the method, a lung phantom with a target object was constructed, and CT-scanned before and after making a shift of the target. The latter scan was intended to simulate a potential organ movement at the time of treatment, and to serve as ground-truth images. Treatment planning using arc-beam delivery was done on the first pCT images. The planned beams were irradiated to the phantom after the shift, while cine transit images were acquired. Cine transit images were also calculated through the pCT images before the shift. From the ratio of the measured and calculated transit images, the amount of image changes due to the organ movement between the time of pCT and that of treatment was three-dimensionally reconstructed. By adding the reconstructed images to the pCT images before the shift, the CT images of the phantom at the time of the beam delivery were generated and compared with the ground truth images. The phantom after the shift was also scanned by on-board cone-beam computer tomography (CBCT) and reconstructed from the measured transit images (MVCT) for comparison. The proposed method reconstructed images that are very close to the ground-truth images in the volume and HU values of the target and the dose-volume coverage of the target and lung. Similar agreement was not found in the CBCT and MVCT images. The method may be used for 4D target image reconstruction, and, combined with the reconstructed image of un-irradiated areas, may offer clinically useful images of the entire region of interest.
机译:本研究的目的是提出一个目标的重建方法及其邻域,其代表放射疗法递送的时刻,基于其在规划计算机断层扫描(PCT)之间的运输图像(PCT)和治疗束递送时间之间的差异。为了验证该方法,构造了具有目标对象的肺幻影,并且在偏移之前和之后CT扫描。后一个扫描旨在在治疗时模拟潜在的器官运动,并用作地面真理图像。使用Acc-Beam输送的处理计划在第一PCT图像上完成。在换档后,计划的梁被照射到幻像,而收购了凝块过境图像。还通过在换档之前通过PCT图像计算了Cine Transit图像。根据测量和计算的传输图像的比率,由于PCT时间与处理时间之间的器官运动和治疗的时,图像变化的量变化是三维重建的。通过在换档之前将重建图像添加到PCT图像中,与地面真理图像相比,生成了光束输送时的幻像的CT图像。换档后的幻像也通过板载锥形束计算机断层扫描(CBCT)扫描并从测量的传输图像(MVCT)重建以进行比较。所提出的方法重建的图像,其非常接近靶的体积和Hu值的地面真实图像和靶和肺的剂量覆盖。 CBCT和MVCT图像中未找到类似的协议。该方法可用于4D目标图像重建,并且与未被辐射区域的重建图像组合,可以提供整个感兴趣区域的临床上有用的图像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号