首页> 外文期刊>Physics in medicine and biology. >Prototype volumetric ultrasound tomography image guidance system for prone stereotactic partial breast irradiation: proof-of-concept
【24h】

Prototype volumetric ultrasound tomography image guidance system for prone stereotactic partial breast irradiation: proof-of-concept

机译:原型容量超声断层扫描图像引导系统,适用于易发定向局部乳房辐照:概念验证

获取原文
获取原文并翻译 | 示例

摘要

Accurate dose delivery in stereotactic partial breast irradiation (S-PBI) is challenging because of the target position uncertainty caused by breast deformation, the target volume changes caused by lumpectomy cavity shrinkage, and the target delineation uncertainty on simulation computed tomography (CT) images caused by poor soft tissue contrast. We have developed a volumetric ultrasound tomography (UST) image guidance system for prone position S-PBI. The system is composed of a novel 3D printed rotation water tank, a patient-specific resin breast immobilization cup, and a 1D array ultrasound transducer. Coronal 2D US images were acquired in 5 degrees increments over a 360 degrees range, and planes were acquired every 2 mm in elevation. A super-compounding technique was used to reconstruct the image volume. The image quality of UST was evaluated with a BB-1 breast phantom and BioZorb surgical marker, and the results revealed that UST offered better soft tissue contrast than CT and similar image quality to MR. In the evaluated plane, the size and location of five embedded objects were measured and compared to MR, which is considered as the ground truth. Objects' diameters and the distances between objects in UST differ by approximately 1 to 2 mm from those in MR, which showed that UST offers the image quality required for S-PBI. In future work we will develop a robotic system that will be ultimately implemented in the clinic.
机译:刻膜部分乳房照射中的准确剂量递送(S-PBI)是挑战,因为乳房变形引起的目标位置不确定度,由肿瘤切除术腔收缩引起的目标体积变化,以及对模拟计算断层扫描(CT)图像的目标描绘不确定性通过差的软组织对比。我们开发了一种容易置位S-PBI的体积超声断层扫描(UST)图像引导系统。该系统由新型3D印刷旋转水箱,患者特异性树脂乳房固定杯和1D阵列超声换能器组成。在360度范围内以5度的增量获得冠状2D,在360度范围内获得,并且在高度升高时每2毫米获得平面。使用超复合技术来重建图像体积。用BB-1乳腺幻影和生物血管外科标记评估了UST的图像质量,结果表明,UST提供比CT和MR类似的图像质量更好的软组织对比。在评估的平面中,测量五个嵌入物体的大小和位置,并与MR相比,MR被认为是地面真理。对象的直径和OST中的物体之间的距离距离MR的物体的距离大约1到2毫米,这表明UST提供了S-PBI所需的图像质量。在未来的工作中,我们将制定一个最终在诊所实现的机器人系统。

著录项

  • 来源
    《Physics in medicine and biology.》 |2018年第5期|共9页
  • 作者单位

    Univ Texas Southwestern Med Ctr Dallas Dept Radiat Oncol Dallas TX 75390 USA;

    Univ Texas Southwestern Med Ctr Dallas Dept Radiat Oncol Dallas TX 75390 USA;

    Univ Texas Southwestern Med Ctr Dallas Dept Radiol Dallas TX USA;

    Univ Texas Southwestern Med Ctr Dallas Dept Radiat Oncol Dallas TX 75390 USA;

    Univ Texas Southwestern Med Ctr Dallas Dept Radiat Oncol Dallas TX 75390 USA;

    Univ Texas Southwestern Med Ctr Dallas Dept Radiol Dallas TX USA;

    Univ Texas Southwestern Med Ctr Dallas Dept Radiat Oncol Dallas TX 75390 USA;

    Univ Texas Southwestern Med Ctr Dallas Dept Radiat Oncol Dallas TX 75390 USA;

    Univ Texas Southwestern Med Ctr Dallas Dept Radiat Oncol Dallas TX 75390 USA;

    Univ Texas Southwestern Med Ctr Dallas Dept Radiat Oncol Dallas TX 75390 USA;

    Univ Texas Southwestern Med Ctr Dallas Dept Radiat Oncol Dallas TX 75390 USA;

    Univ Texas Southwestern Med Ctr Dallas Dept Radiat Oncol Dallas TX 75390 USA;

    Univ Texas Southwestern Med Ctr Dallas Dept Radiat Oncol Dallas TX 75390 USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 R35;
  • 关键词

    ultrasound; tomography; image-guided radiotherapy; stereotactic partial breast irradiation;

    机译:超声波;断层扫描;图像引导放疗;立体定向部分乳房辐照;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号