首页> 外文期刊>Current Microbiology: An International Journal >Evaluation of Petrifilm (TM) Aerobic Count Plates as an Equivalent Alternative to Drop Plating on R2A Agar Plates in a Biofilm Disinfectant Efficacy Test
【24h】

Evaluation of Petrifilm (TM) Aerobic Count Plates as an Equivalent Alternative to Drop Plating on R2A Agar Plates in a Biofilm Disinfectant Efficacy Test

机译:在生物膜消毒功效测试中评估Petrifilm(TM)有氧计数板作为R2A琼脂板上滴板的等效替代品

获取原文
获取原文并翻译 | 示例
           

摘要

This paper compares Petrifilm (TM) aerobic count (AC) plates to drop plating on R2A agar plates as an alternative method for biofilm bacteria enumeration after application of a disinfectant. A Pseudomonas aeruginosa biofilm was grown in a Centers for Disease Control and Prevention biofilm reactor (ASTM E2562) and treated with 123 ppm sodium hypochlorite (as free chlorine) according to the Single Tube Method (ASTM E2871). Aliquots from the same dilution tubes were plated on Petrifilm (TM) AC plates and drop plated on R2A agar plates. The Petrifilm (TM) AC and R2A plates were incubated for 48 and 24 h, respectively, at 36 +/- 1 degrees C. After nine experimental runs performed by two technicians, the mean difference in biofilm log densities [log biofilm density (LD) = log(10)(CFU/cm(2))] between the two methods for control coupons, treated coupons, and log reduction (LR) was 0.052 (p = 0.451), -0.102 (p = 0.303), and 0.152 (p = 0.313). Equivalence testing was used to assess equivalence of the two plating methods. The 90 % confidence intervals for the difference in control and treated mean LDs between methods were (-0.065, 0.170) and (-0.270, 0.064), both of which fall within a (-0.5, +0.5) equivalence criterion. The 90 % confidence interval for the mean LR difference (-0.113, 0.420) also falls within this equivalence criterion. Thus, Petrifilm (TM) AC plates were shown to be statistically equivalent to drop plating on R2A agar for the determination of control LDs, treated LDs, and LR values in an anti-biofilm efficacy test. These are the first published results that establish equivalency to a traditional plate counting technique for biofilms and for a disinfectant assay.
机译:本文比较了Petrifilm(TM)有氧计数(AC)板和R2A琼脂板上的滴板,作为应用消毒剂后生物膜细菌计数的另一种方法。铜绿假单胞菌生物膜在疾病控制与预防中心生物膜反应器(ASTM E2562)中生长,并根据单管法(ASTM E2871)用123 ppm次氯酸钠(作为游离氯)处理。将来自相同稀释管的等分试样铺在Petrifilm TM AC板上,并滴入R2A琼脂板上。将Petrifilm(TM)AC和R2A板分别在36 +/- 1摄氏度下孵育48和24 h。在两名技术人员进行9次实验运行之后,生物膜对数密度的平均差异[log生物膜密度(LD) )= log(10)(CFU / cm(2))]的两种用于控制附单,已处理附单和对数减少(LR)的方法分别为0.052(p = 0.451),-0.102(p = 0.303)和0.152 (p = 0.313)。等效测试用于评估两种电镀方法的等效性。方法之间的对照和处理后平均LD差异的90%置信区间为(-0.065,0.170)和(-0.270,0.064),两者均在(-0.5,+0.5)等效标准之内。平均LR差(-0.113,0.420)的90%置信区间也落入此等效标准内。因此,在抗生物膜功效测试中,Petrifilm(TM)AC板在统计学上等同于R2A琼脂滴板,用于确定对照LD,处理后的LD和LR值。这些是首次发表的结果,与生物膜和消毒剂测定的传统平板计数技术相当。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号