首页> 外文期刊>Spine >Reproducibility of rasterstereography for kyphotic and lordotic angles, trunk length, and trunk inclination: a reliability study.
【24h】

Reproducibility of rasterstereography for kyphotic and lordotic angles, trunk length, and trunk inclination: a reliability study.

机译:KyStereReportography的再现性,脊柱和主角,树干长度和躯干倾向:可靠性研究。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY DESIGN: Determination of reliability with 3 investigators using a collective of healthy volunteers. OBJECTIVE: To determine the reliability of rasterstereography 3-dimensional back surface analysis and reconstruction of the spine in healthy test subjects. SUMMARY OF BACKGROUND DATA: Rasterstereography has been in clinical use since 1989 for patients with scoliosis and other spinal deformities and it significantly reduces the need for otherwise indispensable radiographs. The validity of this device has previously been examined in other studies. This study was performed to evaluate the reliability of rasterstereography for clinical application in diagnostic and follow-up examinations. METHODS: Fifty-one healthy volunteers were examined rasterstereographically by 3 investigators. Each investigator made a series of 3 measurements of each participant in which 8 spine parameters including kyphotic angle ICT-ITL (max.), kyphotic angle VP-ITL, kyphotic angle VP-T12, lordotic angle ITL-ILS (max.), lordotic angle ITL-DM, lordotic angle T12-DM, trunk length VP-DM and trunk inclination were measured. Cronbach alpha was calculated. The influence of high or low body mass index on the accuracy of the technique was evaluated as well. RESULTS: Cronbach alpha for the intratester-reliability of the kyphotic angle ICT-ITL (max.) for the 3 investigators has values between 0.921 and 0.992. The intertester-reliability for the same parameter is 0.979 (95% CI). In this study group a meaningful association between body mass index and reliability of the device was not found. CONCLUSION: The reliability revealed very good results, both for intratester and for intertester reliability. The technique is well suited for analysis of the back in standing position. The body mass index has no influence on the reproducibility.
机译:研究设计:使用健康志愿者的集体确定3个调查人员的可靠性。目的:确定健康检测科目中拉斯特雷铸造术三维背面分析及重建脊柱的可靠性。背景数据摘要:自1989年以来一直在临床使用中,针对脊柱侧凸和其他脊柱畸形的患者,它显着降低了不可缺少的X线片。此前研究了该设备的有效性。进行该研究以评估诊断和后续检查中临床应用的临床应用的可靠性。方法:3个调查人员检查了五十一位健康志愿者。每个调查员对每个参与者进行了一系列3测量,其中8个脊柱参数,包括Kyphotic角度ICT-ITL(最大值),Kyphotic角度VP-ITL,Kyphotic角度VP-T12,Lorditic Antge ITL-ILS(MAX。),Lordotic测量角度ITL-DM,雄靴角T12-DM,树干长度VP-DM和行李箱倾斜度。计算Cronbach alpha。还评估了高或低体重指数对技术精度的影响。结果:Cronbach Alpha为3个调查人员的Kyphic角ICT-ITL(最大值)的可靠性有0.921和0.992之间的值。相同参数的纠结性可靠性为0.979(95%CI)。在本研究中,找不到体重指数和设备的可靠性之间的有意义的关联。结论:可靠性揭示了对肠内肠和间歇性可靠性的非常好的结果。该技术非常适合于分析站立位置。体重指数对重现性没有影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号