首页> 外文期刊>Current Microbiology: An International Journal >Routine sampling and the control of Legionella spp. in cooling tower water systems
【24h】

Routine sampling and the control of Legionella spp. in cooling tower water systems

机译:常规采样和军团菌的控制。在冷却塔水系统中

获取原文
获取原文并翻译 | 示例
           

摘要

Cooling water samples from 31 cooling tower systems were cultured for Legionella over a 16-week summer period. The selected systems were known to be colonized by Legionella. Mean Legionella counts and standard deviations were calculated and rime series correlograms prepared for each system. The standard deviations of Legionella counts in all the systems were very large, indicating great variability in the systems over the time period. Time series analyses demonstrated that in the majority of cases there was no significant relationship between the Legionella counts in the cooling tower at time of collection and the culture result once it was available. In the majority of systems (25/28), culture results from Legionella samples taken from the same systems 2 weeks apart were not statistically related. The data suggest that determinations of health risks from cooling towers cannot be reliably based upon single or infrequent Legionella tests. [References: 16]
机译:在16周的夏季期间,对来自31个冷却塔系统的冷却水样本进行了军团菌培养。已知所选系统被军团菌定殖。计算平均军团菌计数和标准差,并为每个系统准备霜谱系列相关图。所有系统中军团菌计数的标准差都很大,表明该系统在一段时间内存在很大的变异性。时间序列分析表明,在大多数情况下,收集时冷却塔中军团菌的计数与培养结果一经获得就没有显着关系。在大多数系统中(25/28),从间隔2周的相同系统中提取的军团菌样品的培养结果在统计学上没有相关性。数据表明,无法通过单例或偶发军团菌检测可靠地确定冷却塔对健康的危害。 [参考:16]